Skip to main content
. 2021 May 24;21(11):3636. doi: 10.3390/s21113636

Table 3.

TTC and PRP results for timestamp issuing of TSAs in a single monitoring application environment.

Sensors Measured Values TSA1 TSA2 TSA3 TSA4 TSA5 TSA6 TSA7
1 TTC (s) 1.280 1.248 1.279 1.295 1.170 1.248 1.154
PRP (%) 78.13 80.13 78.19 77.22 85.47 80.13 86.66
5 TTC (s) 1.264 1.264 1.295 1.311 1.185 1.295 1.154
PRP (%) 79.11 79.11 77.22 76.28 84.39 77.22 86.66
10 TTC (s) 1.326 1.279 1.279 1.372 1.202 1.280 1.139
PRP (%) 75.41 78.19 78.19 72.89 83.19 78.13 87.80
15 TTC (s) 1.279 1.311 1.315 1.310 1.201 1.280 1.301
PRP (%) 78.19 76.28 76.05 76.34 83.26 78.13 76.86
20 TTC (s) 1.279 1.295 1.306 1.373 1.170 1.326 1.366
PRP (%) 78.19 77.22 76.60 72.83 85.47 75.41 74.85
Average value TTC (s) 1.286 1.279 1.295 1.332 1.186 1.286 1.217
PRP (%) 77.81 78.19 77.24 75.11 84.36 77.80 82.56