Skip to main content
. 2020 Jun 5;45(9):2726–2735. doi: 10.1007/s00261-020-02599-z

Table 4.

Accuracy in predicting shunt procedure including anastomotic variants

O1 O2
Accuracy of shunt procedures recommended on the basis of CT and/or MRI
 1st option
  CT 73% 52%
  MRI 80% 60%
  p value 0.728 0.756
 1st + 2nd option
  CT 88% 76%
  MRI 100% 73%
  p value 0.294 1.000
Accuracy of suggested shunts and proposed anastomotic variant
 1st option
  CT 64% 36%
  MRI 53% 33%
  p value 0.538 1.000
 1st + 2nd option
  CT 79% 67%
  MRI 73% 60%
  p value 0.720 0.749