Table 4.

Letter acuity scores and comparisons between AQP4 non-ON and HC eyes

Letter acuity score HC median (IQR) (n=116 eyes) AQP4 non-ON median (IQR) (n=70 eyes) AQP4 non-ON vs HC
Beta (95% CI)a P-valuea
100% contrast (HCLA) 59 (55–64) 55 (49–62) −3.63 (−6.13 to −1.13) 0.004
2.5% contrast (LCLA) 33 (25–37) 24.5 (14–32) −6.80 (−9.92 to −3.67) <0.001
1.25% contrast (LCLA) 20 (13.5–27.5) 9 (3–20) −5.32 (−10.75 to 0.11) 0.055
a

Derived from generalized estimating equation models, adjusted for age, sex and race

HC: healthy controls; AQP4: aquaporin-4; ON: optic neuritis; IQR: interquartile range; CI: confidence interval; HCLA: high-contrast letter acuity; LCLA: low-contrast letter acuity