Skip to main content
. 2021 May 3;22(6):172–182. doi: 10.1002/acm2.13224

Table 1.

Dosimetric parameters of 125I seed implantation using the "Ten‐step method” at 1 month and calculated BED in 137 cases

Number of seed LDR monotherapy n = 137
Variables Mean (range) at seed implantation Mean (range) at one month after seed implanation
Prostate D90 (Gy) 196.2 (173–207.5) 194.1 (156.9–223.8)
BED (Gy) 209.7 (183.5–222.6) 207.3 (165.5–241.4)
V100 (%) 99.8 (98.1–100) 99.0 (94.1–100)
UD30 (Gy) 201.3 (175.1–224.2) 211.7 (155.7–263.2)
R100 (cc) 0.23 (0–1.07) 0.47 (0–2.03)

Average prostate volume (range) of 137 cases is 32.9 (15‐77.0) cm3. D90: minimal dose (Gy) received by 90% of the prostate. BED: biologically effective dose. V100: The percentage prostate volume receiving 100% of the prescribed minimal peripheral dose; UD30: Minimal dose (Gy) received by 30% of the urethra; R100: Rectal volume (cm3 ) receiving 100% of the prescribed dose. Average (range) of air‐kerma strength of the implanted seeds is 0.390 (U): range 0.361–0.501 (U). Average number (range) of implanted seeds is 102 (75–144).