Skip to main content
. Author manuscript; available in PMC: 2021 Jun 15.
Published in final edited form as: Int J Hyperthermia. 2020;37(1):799–807. doi: 10.1080/02656736.2020.1784471

Table 2:

Mean diameter (range, mm) at the completion of ablation and at each post-ablation time point (Note: MW numbers include ablation performed at 70W and 140W)

Completion of ablation 2 minutes post 5 minutes post 10 minutes post
Visible gas MW US 21.6
(15.0–28.9)
10.2
(4.1–19.6)
7.6
(3.8–12.7)
5.3
(2.7–13.8)
CT 16.7
(10.2–28.1)
7.5
(4.1–21.0)
3.0
(0–9.6)
1.2
(0–7.1)
Visible gas RF US 14.7
(10.4–19.5)
6.2
(3.4–11.5)
4.0
(2.8–5.7)
3.5
(2.3–5.4)
CT 7.2
(3.0–12.7)
1.9
(0–5.5)
0
(0–0)
0
(0–0)
Hypoechoic/ hypoattenuating MW US 24.5
(17.3–31.3)
23.2
(18.5–29.5)
23.3
(18.4–29.6)
23.0
(14.7–29.6)
CT 30.0
(23.4–42.3)
29.9
(18.4–43.1)
29.4
(20.8–41.2)
28.1
(13.9–40.9)
Hypoechoic/ hypoattenuating RF US 18.0
(11.5–23.3)
17.2
(11.7–21.6)
17.5
(11.9–23.6)
17.2
(12.6–21.9)
CT 18.8
(8.9–23.3)
19.0
(10.4–25.9)
19.7
(9.0–25.6)
19.1