Table II.

Relative uncertainty and relative difference between measurement (uW, norm) and Model (with Tilde)

Unloaded Chamber Loaded Chamber
Relative uncertainty (linear units) Relative difference (percent) Relative uncertainty (linear units) Relative difference (percent)
uW, norm 0.058 -- 0.197 --
u˜W,unloaded (15) 0.0065 88.7 0.026 98.6
u˜W,loaded (16) 0.068 17.2 0.253 28.4
u˜W,loaded_[3] (17) 0.072 24.1 0.320 62.4