Skip to main content
. Author manuscript; available in PMC: 2021 Jun 15.
Published in final edited form as: J Magn Reson Imaging. 2020 Nov 15;53(4):1130–1139. doi: 10.1002/jmri.27421

TABLE 1.

CS Algorithm Image Reconstruction Performance

nRMSE (Images) (N = 8)
AF=2 AF=5 AF=10 Average iterations Average time (s)
STFD 0.0184 0.0329 0.0437 181 206 s
EXP 0.0158 0.0373 0.0595 400 153 s
WAV 0.0168 0.0323 0.0471 161 119 s
LOW 0.0174 0.0338 0.0479 200 75 s
LPS-SFD 0.0224 0.0363 0.0604 160 155 s

The table summarizes the nRMSE for the algorithms used at the AFs tested. The computational cost in the number of iterations used and the average time for those iterations are shown. The lowest errors for each AF are marked in bold.