Table 4. Association Constants for Duplex Formation between Sequence-Complementary 3-mers Measured by ITC Titration Experiments in Toluene at 298 Ka.
complex | log K (M–1) | ΔG° (kJ mol–1) | ΔH° (kJ mol–1) | ΔS° (J K–1 mol–1) |
---|---|---|---|---|
AAA·DDD | 5.2 | –29.5 | –57 | –92 |
AAD·ADD | 4.2 | –23.9 | –45 | –71 |
ADA·DAD | 4.3 | –24.6 | –50 | –85 |
Errors based on repeat experiments are 0.1 in log K, 0.5 kJ mol–1 in ΔG°, 5 kJ mol–1 in ΔH°, and 20 J K–1 mol–1 in ΔS°.