Abstract
High-molecular-weight polymeric nanoparticles are critical to increasing the loading efficacy and tuning the release profile of targeted molecules for medical diagnosis, imaging, and therapeutics. Although a number of microfluidic approaches have attained reproducible nanoparticle synthesis, it is still challenging to fabricate nanoparticles from high-molecular-weight polymers in a size and structure-controlled manner. In this work, an acoustofluidic platform is developed to synthesize size-tunable, high-molecular-weight (>45 kDa) poly (lactic-co-glycolic acid)-b-poly (ethylene glycol) (PLGA-PEG) nanoparticles without polymer aggregation by exploiting the characteristics of complete and ultrafast mixing. Moreover, the acoustofluidic approach achieves two features that have not been achieved by existing microfluidic approaches: (1) multi-step (≥2) sequential nanoprecipitation in a single device, and (2) synthesis of core-shell structured PLGA-PEG/lipid nanoparticles with high molecular weights. The developed platform expands microfluidic potential in nanomaterial synthesis, where high-molecular-weight polymers, multiple reagents, or sequential nanoprecipitations are needed.
An acoustofluidic platform is developed to synthesize high-molecular-weight polymeric nanoparticles in a size- and structure-controlled manner, while eliminating polymer aggregation within the microchannel.
S. Zhao, P.H. Huang, H. Zhang, J. Rich, H. Bachman, J. Ye, W. Zhang, C. Chen, Z. Xie, Z. Tian, P. Kang, H. Fu, T. J. Huang
Graphical Abstract

Introduction
Polymeric nanoparticles are capable of encapsulating and delivering thousands of therapeutic molecules per particle for therapeutics, imaging, and medical diagnosis.1 Based on advanced chemical modification technologies,2,3 polymers can be engineered with controlled molecular weights.4–6 Among different nanoparticles, high-molecular-weight polymeric nanoparticles can increase drug loading, prolong circulation half-life, and extend the drug release profile, and thus play an indispensable role in therapeutic nanosystems.4,7–12 Using bulk synthesis methods, high-molecular-weight poly (lactic-co-glycolic acid) (PLGA) nanoparticles (>45 kDa) have been utilized in both research and biological applications. 3,10–12 Multi-step bulk synthesis methods also allow the design of novel multifunctional nanomedical systems from high-molecular-weight polymers.13,14 However, these bulk methods suffer from batch-to-batch inconsistencies and polydisperse outcomes.15,16
Benefiting from microscale fluid environments, microfluidic platforms provide a promising alternative for reproducible polymeric nanoparticle synthesis.17–26 To date, microfluidic methods have demonstrated tremendous success in high-throughput synthesis of budesonide nanoparticles27 and reproducible nanoparticle synthesis from various amphiphilic polymer systems, including poly (lactic-co-glycolic acid)-b-poly (ethylene glycol) (PLGA-PEG),28,29 lipid vesicles,30,31 and chitosan.32
Despite the above-mentioned achievements, microfluidic methods still have several deficiencies in synthesizing polymeric nanoparticles. First, high molecular weight polymers tend to aggregate within microchannels and thus the corresponding nanoparticles are difficult to fabricate through microfluidics.4 As a result, current microfluidic methods tend to mainly focus on synthesizing nanoparticles from low-molecular-weight polymers.28,29,32 Taking the most widely utilized 2D hydrodynamic flow focusing (HFF) method as an example, high-molecular-weight polymers are concentrated along boundary interfaces and lead to channel fouling.4,32 Although 3D HFF microfluidic devices were specifically designed to address high-molecular-weight polymer aggregation, these devices require precise control of the 3D fluid flow profile.1,4 Second, difficulties remain in generating structured nanoparticles, such as two-layer or even three-layer nanoparticles. For 2D HFF, the sidewall sheath fluids impede it from the capability to sequentially assemble hierarchical nanoparticles.28,30 Usually, multiple microfluidic devices are applied. By employing two separate HFF and Tesla microfluidic devices, researchers realized sequential polymer assembly, but the intermediate procedures complicate fabrication and increase uncertainty.5 Therefore, developing new microfluidic methods to generate nanoparticles in a size and structure controlled manner from high-molecular-weight polymers is necessary.
In this work, we present a 2D acoustofluidic (i.e., the fusion of acoustics and microfluidics)33–41 platform for the synthesis of PLGA based nanoparticles with controlled size and structure, while eliminating polymer aggregation. Different from hydrophilic glass microchannels,6,42,43 our method exploits complete and ultrafast micromixing to address polymer aggregation within the entire microchannel instead of only at the microchannel wall. By oscillating microscale sharp-edges with acoustic waves, our devices generate micro-vortex streaming to completely mix reagents in the entire microchannel.44,45 To achieve rapid mixing, the dependence of mixing performance on the device configurations was systematically investigated, including glass thickness, PDMS thickness, and sharp-edge structure. The robustness of the device was confirmed by numerical and experimental results of viscous polymer solution mixing. Using the fine-tuned devices, we synthesized PLGA-PEG nanoparticles with a tunable size without aggregation from high-molecular-weight polymers. These nanoparticles are difficult to fabricate by existing microfluidic methods or bulk methods.4 Additionally, our devices synthesized core-shell PLGA-PEG/lipid nanoparticles, providing a new method for sequential nanoprecipitation in a single device. With its 2D structure, and complete, sequential, rapid (<10 ms) micromixing, our acoustofluidic synthesis platform can harness the benefits of microfluidics in a wider variety of scenarios, such as synthesis of high-molecular-weight polymers, multiple reagents, and sequential nanoprecipitation.
Materials and Methods
Chemicals
PLGA10K-PEG5K (AI056), PLGA50K-PEG5K (AI184), PLGA70K-PEG2K (AI080), and PLGA (5K-10K, AI017) were purchased from PolySciTech (Akina Inc., West Lafayette, IN, USA). PLGA90K-PEG10K was purchased from Creative PEGWorks (DLG-10k90k31, NC, USA). 1,2-dipalmitoyl-sn-glycero-3-phosphocholine (DPPC, ~733 Da, 850355) and phosphoethanolamine-N-[methoxy (polyethylene glycol)-2000 (DSPE-PEG2000, ~2780 Da, 880135) were purchased from Avanti Poplar Lipids (Alabaster, AL). Cholesterol (C8667, ~386 Da), Purified water (W4502), and PEGDA700 (455008) were purchased from Sigma-Aldrich (MO, USA). Ethanol was purchased from VWR, USA. Phosphate-buffered saline (PBS) was purchased from Life Technologies (2046802, 10X, USA). Acetonitrile was purchased from Grainger (26WD84, NC, USA). For the synthesis of PLGA-PEG nanoparticles, PLGA10K-PEG5K, PLGA50K-PEG5K, and PLGA90K-PEG10K were dissolved in acetonitrile with a concentration from 10 mg/mL to 90 mg/mL.
Device Fabrication
In this study, a piezoelectric element with a resonant frequency of 2.0 kHz was used as acoustic transducer (AB2720B-LW100-R. PUI Audio Inc., OH, USA). To fabricate the microchannel with sidewall sharp-edges, a SU8 mold was first prepared by standard photolithography and deep reactive ion etching. Then, the mixture of PDMS base and curing agent at a ratio of 10:1 (Sylgard 184, Dow Corning, MI, USA) was degassed and poured on the SU8 mold. Once cured at 65 °C for 1 h, the PDMS microchannel was peeled and bonded on a cover glass by oxygen plasma treatment. After that, the stack of the cover glass and the PDMS microchannel was baked at 65 °C for 12 h. Finally, an acoustic transducer was bonded on the same covers glass adjacent to PDMS channel using epoxy (PermaPoxyTM 5 Minute General Purpose, Permatex).
Experimental Setup
The acoustofluidic device was placed on the stage of an inverted microscope (Eclipse Ti, Nikon, Japan). The injection of different fluid flows into microchannel was govern by a neMESYS syringe pump (cetoni GmbH, Germany). Before each experiment, isopropyl alcohol (IPA) was used to flush the whole channel to eliminate air bubbles. The acoustic transducer was excited by magnified square wave signals from a function generator (AFG3011, Tektronix, USA) and an amplifier (25A250A, Amplifier Research, USA). Unless otherwise indicated, the working frequency was set at 4 kHz and the driving voltage was kept at 25 VPP.
To characterize the mixing performance of our device, DI water and fluorescent dye were injected through independent inlets into the microchannel. Unless otherwise specified, the flow rates of DI water and fluorescent dye were both 15 μL/min (30 μL/min in total). The mixing performance was then quantitatively characterized by the standard deviation of normalized gray scale values. Here, we systematically investigate the influence of the device parameters (PDMS thickness, glass thickness, and sharp-edge number, height, and distance) and the operation parameters (driving frequency and voltage) on the mixing performance. The microchannel for all experiments was 100 μm high, 600 μm wide, and 1 cm long, and the tip angle of sharp-edges were fixed to 15°. The No. 1 (130–170 μm, 48404–453, VWR, USA) and No. 2 (170–250 μm, 48382–136, VWR, USA) cover glasses were purchased from VWR, while the No. 0 cover glasses were purchased from Thor Labs (85–115 μm, CG00K1, Thorlabs, Inc., USA).
PLGA-PEG Nanoparticle Synthesis
For PLGA-PEG nanoparticle synthesis, three 1.0 mL syringes for polymer precursor solution and water were co-injected into the microchannel. The flow ratio for polymer and water was maintained at 1:10, unless otherwise indicated. The frequency for acoustofluidic device was set to approximately 4.0 kHz and the input voltage was 38 VPP. To synthesize nanoparticles by 2D HFF, we fabricated microchannels with the identical geometry as the acoustofluidic device, except for the absence of sharp-edges. The flow rates of the polymer stream and the two water sheath streams were maintained at 1 μL/min and 50 μL/min, respectively, keeping a flow ratio of 1:100 for polymer stream to aqueous stream. For the synthesis of nanoparticles by bulk methods, 10 μL of polymer solution were mixed with 100 μL water solution using a vortex mixer (MX-S, Scilogex, USA) for 1 min.
PLGA-PEG/Lipid Core-Shell Nanoparticle Synthesis
For PLGA-PEG/lipid core-shell nanoparticle synthesis, PLGA70K-PEG2K was dissolved in acetonitrile with a concentration of 2.5 mg/mL. The lipid solution, which composed of DPPC, DSPE-PEG2000, and cholesterol, were dissolved in ethanol at a concentration of 0.8 mg/mL, 0.8 mg/mL, and 1 mg/mL, respectively. To prevent aggregation between high-molecular-weight hydrophobic PLGA chains, polymers with a PEG chain is needed. Meanwhile, the surface areas of PLGA nanoparticles should be largely uncovered and exposed, to provide driving force for lipid-PLGA assembly by their hydrophobic attraction between the PLGA and the lipid tail.46 Based on a previous publication,47 a high ratio of PLGA to PEG (>10:1) can lead to partial coverage of PEG on the surface of PLGA nanoparticles. Thus, an ultra-high ratio of PLGA to PEG ratio (35:1) was chosen. The synthesis of core-shell nanoparticles included two stages with three inlets and one outlet. First, the solution of PLGA-PEG and water were separately injected into inlets and mixed to generate PLGA-PEG core. Second, lipid solution was injected in one middle inlet for self-assembly of lipid shell on the polymer core. The operation voltage was 45 VPP and the flow rate of water was 20 μL/min. For liposome and PLGA70K-PEG2K nanoparticle synthesis, the flow rates were both 3 μL/min. For PLGA-PEG/lipid nanoparticle synthesis, the flow rate of PLGA-PEG solution was kept at 3 μL/min, while that of lipid solution increased from 1 μL/min to 7 μL/min. For the nanoparticles stability studies in PBS and water, 25 μL of 10X PBS is pipetted into 50 μL PLGA70K-PEG2K solution or PLGA70K-PEG2K/lipid synthesized at a lipid flow rate of 1 μL/min, while three consecutive additions of 25 μL of 10X PBS were added into 50 μL PLGA70K-PEG2K/lipid and liposome solution, respectively.
Sample Characterization
For sample characterization, the average size and size distribution were measured with the Malvern Zetasizer (Malvern Instruments, UK). For each measurement, 50 μL of the sample was pipetted in a Malvern cuvette (NC0628994, Fischer Scientific, USA). At least three measurements were conducted for each sample. For TEM imaging, 10 μL of the synthesized nanoparticle suspension was placed on a 300-mesh copper grid (CF300-Cu, Electron Microscopy Sciences, USA). After 10 min of incubation, a parafilm sheet was used to adsorb the excessive nanoparticle solution. Then, the grid was negatively stained with uranyl-acetate solution for 15 min. Finally, the grid was washed twice using distilled water and dried at room temperature. The morphology of the sample was then observed using a Tecanai G2 Twin TEM (FEI, USA).
Results and discussion
Principle of the Acoustofluidic Synthesis Platform
Figure 1A shows the schematic design of the acoustofluidic synthesis platform. A PDMS microchannel with sidewall sharp-edges and an acoustic transducer are bonded adjacently on a cover glass (Figure S1).48 When a driving voltage is applied, vibration from the acoustic transducer oscillates sharp-edges within a microchannel (Video S1). This oscillation generates acoustic micro-vortex streaming to mix amphiphilic polymer solution and its anti-solvents (Figure 1A).49,50 The amphiphilic polymers then self-assemble into nanoparticles. During this process, the hydrophobic polymer chains are excluded from surrounding hydrophilic water molecules and arrange into hydrophobic cores, while the hydrophilic chains extend into water molecules and function as a steric hindrance layer to prevent aggregation between the hydrophobic cores3,51,52 (Figure 1B).
Fig. 1.
Design and working principle of the acoustofluidic synthesis platform. (A) Schematic of high molecular weight polymeric nanoparticle synthesis using micro-vortex streaming. (B) Illustrative figure of the synthesized nanoparticle component layers, where the hydrophilic layer is used to prevent aggregation between high molecular weight hydrophobic polymer chains. (C) Stacked image of 10 pictures over 100 ms for 1.9 μm fluorescent beads trajectories showing the acoustic micro-vortex streaming. Scale bar: 200 μm. (D) With acoustics off, a laminar flow is observed in the microchannel. Scale bar: 200 μm. (E) With acoustics on, three-step sequential micromixing is achieved in a single device. In each step, different fluids are completely mixed at the tip of the first sharp edge structure they encountered. Scale bar: 200 μm.
To prevent high-molecular-weight polymer aggregation within a microchannel, the acoustofluidic devices exploit complete, rapid micromixing to achieve successful polymer self-assembly and preserve the hydrophilic shell and hydrophobic core structure in Figure 1B. In 2D HFF, precipitated polymers are highly concentrated into a small interfacial region and numerous polymers entangle with each other, resulting in polymer aggregation.4,32 Using our micro-vortex streaming based devices (Figure 1C), the solvent exchange of polymer solution and its anti-solvent is completed within an entire microchannel (Figure 1D and 1E). This complete mixing disperses precipitated polymers uniformly within an entire microchannel and reduces random polymer entanglements, allowing the successful self-assembly of high-molecular-weight polymers. In terms of mixing time, bulk methods suffer from polydispersity due to slow mixing.10–12 This slow mixing creates a non-uniform reaction environment and a temporally lengthy self-assembly process, leading to inhomogeneous nanoparticles larger than 200 nm.4 Instead, our acoustofluidic devices completely mix laminar fluids at the tip of the first sharp-edge they encounter, when acoustics switch from off to on (Figure 1D and 1E). This rapid, complete micromixing provides a uniform reaction condition for monodisperse synthesis of high-molecular-weight polymeric nanoparticles, and then the hydrophilic surface layer on synthesized nanoparticles prevents aggregation via steric hindrance effect.
Another important feature of this acoustofluidic device is its ability to perform sequential nanoprecipitation. Considering that each micro-vortex streaming can serve as a mixing site, multiple-step (≥2) nanoprecipitation can be achieved conveniently by introducing middle inlets into microchannels (Figure 1E and Video S2). This unique feature is critical for the future design of novel therapeutic compounding nanosystems, such as three-layer multifunctional nanoparticles from the combination of lipid/stimuli responsive peptide53,54 and PLGA/lipid nanoparticles13,14.
With the ability to exclude polymer aggregation, our acoustofluidic synthesis devices provide a pragmatic platform for synthesizing size- and structure-controllable nanoparticles from high-molecular-weight polymers, while maintaining the uniform reaction environment of microfluidics. These features are different from that demonstrated in our previous publication29 (Table S1). Undoubtedly, the ultimate homogeneity and reproducibility of nanoparticles depend on the performance of the acoustofluidic synthesis device, that is, the mixing time. Therefore, we first focused on optimizing the device design parameters to reduce mixing time and improve nanoparticle performance.
Rational Acoustofluidic Design to Improve Mixing Performance
Rapid mixing contributes to reproducible nanoparticle synthesis by providing a homogenous condition for the nucleation and growth of nanoparticles.28,55 The mixing time in our device is strongly related to the micro-vortex streaming intensity. To decrease mixing time, we enhanced the acoustic streaming by designing rational device parameters. Here, two inlets were used for simplicity. We first determined the driving frequency by sweeping the input frequency from 2 kHz to 6 kHz with a minimum 100 Hz increment. The mixing performance was quantitatively characterized by the mixing index (M) (Figure S2) based on Equation 129,56:
| (1) |
Here, n, Ii, and Im represent the sampled points along a line, the gray scale value of a point, and the averaged gray scale value of the line, respectively. A M of 0.1 is the cut off value for complete mixing, while M values of 0.0 and 0.5 correspond to completely mixed and unmixed fluids, respectively.29 When excited with a 3.9 kHz signal, devices achieved the lowest M of 0.05 (Figure S2). As such, 3.9 ±0.2 kHz was chosen as the driving frequency range to excite the different devices; the small frequency range was adopted due to the slight frequency shifts required for excitation of devices with different design parameters.
Then, the influence of sharp-edge design was evaluated. Figure 2A shows that devices with sharp-edge height (H) of 300 μm always retain the best mixing performance. This phenomenon is ascribed to larger vibration displacement in devices with larger H.44,57 In Figure 2B, devices with a moderate sharp edge spacing (S) of 600 μm show the best mixing performance. Considering the fixed length range of sharp-edges, a large S reduces the mixing sites and thus compromises the mixing performance, while a small S generates micro-vortex streaming close to each other and can suppress acoustic streaming. In Figure 2C, with increased sharp-edge pairs and mixing sites, N, the mixing performance is gradually improved. Although there is almost no difference between N=8 and 12 in Figure 2C, devices with N=12 was selected due to its slightly better performance at certain conditions, such as complete mixing at 35 μL/min and 25 VPP.
Fig. 2.
Rational design of device parameters by the characterization of mixing performance of the acoustofluidic devices. Plots of mixing indexes at different driving voltages with (A) different sharp-edge heights, (B) spacing between sharp-edges, and (C) different numbers of sharp-edge pairs. Here, 4 mm thick PDMS, No. 2 glass, and 30 μL/min total flow rate are applied for (A, B, and C). Plots of mixing indexes with different device and operation parameters: (D) glass thickness with 4 mm thick PDMS, (E) PDMS thickness with No. 2 glass, and (F) driving voltage with 4.6 mm thick PDMS and No. 2 glass. The sharp-edge structure is 300×600×12 for (D, E, F) and the total flow rate is 30 μL/min for (A, B). The thickness is 85–115 μm, 130–170 μm, and 170–250 μm for No. 0, No. 1, and No. 2 glasses, respectively. The sharp-edge structure, depending on the height (H) in μm, spacing (S) in μm, and number of sharp-edge pairs (N), is denoted as H×S×N. Data represents average of n = 3 independent devices ± standard deviation.
With the determined sharp-edge structure of 300 μm ×600 μm ×12 pairs, we further investigated the influence of glass thickness, PDMS thickness, and driving voltages. From Figure 2D and 2E, the mixing performance strongly depends on the glass and PDMS thickness. The best performance appears at 170–250 μm thickness for No.2 glass and 4.6 mm thickness for PDMS. The influence of glass and PDMS thickness can be understood by approximating the vibration of the acoustofluidic devices as a harmonic motion. As the PDMS thickness (mass) is increased, its vibration frequency decreases.58 At a suitable thickness of glass and PDMS, the vibration frequency of the system matches well with the excitation frequency, and strong resonance vibration mode appears. Due to the non-linear characteristics of a resonance system, the mixing performance depends nonlinearly on the device parameters. Devices with 300 μm ×600 μm ×12 pairs, 4.6 mm PDMS, and No. 2 (170–250 μm) glass were subsequently applied. In Figure 2F, with increasing voltages, the maximum flow rate for complete mixing was 90 μL/min at 35 VPP and 150 μL/min at 50 VPP (Video S1), respectively. The average mixing time τ was also estimated by Equation 2.59
| (2) |
Here, dmix is the distance from unmixed to totally mixed regions, and Vavg is the average fluid velocity. At 150 μL/min, τ was calculated to less than 12 ms, being consistent with the experimental value of 11.88 ms (Figure S3a and Video S1). At 90 μL/min, τ exhibited a calculated and experimental value of approximate 8.07 ms and less than 9.9 ms, respectively (Figure S3b). In previous microfluidic-based synthesis methods, τ was 189 ms in surface acoustic waves based device,60 400 ms in 2D HFF device,32 7–53 ms for turbulent jet platform,61 and 4–25 ms in star-based acoustic micromixer.27 These results indicate that our acoustofluidic device can provide efficient and ultrafast reagent mixing for polymeric nanoparticle synthesis.
Numerical and Experimental Investigation on Acoustofluidic Mixing of Highly Viscous Polymers
Considering the high molecular weight and high concentration of polymer precursors for nanoparticle synthesis, the performance of the rational acoustofluidic devices was further verified by numerical and experimental investigation of the mixing between viscous PEGDA700 and water solutions. Based on the perturbation approach developed in our previous publications,57,62 the simulation was performed using COMSOL 5.3 (the COMSOL Group). The viscosity of PEGDA700 is 95.9 mPa.s, which is much higher than that of water (0.89 mPa.s)63 and that of PLGA solution (6.7 mPa.s for 33K PLGA).64 We diluted the PEGDA700 solutions from 0% to 50% using DI water before the on-chip acoustofluidic mixing (Figure S4).63 For all measurements, the driving voltage is kept at 50 VPP, and the total flow rate was fixed at 6 μL/min. A 50% PEGDA-water solution (viscosity 18.3 mPa.s) was injected into one inlet as μ1, while PEGDA solution with varying concentrations was injected into another inlet as μ2 (Figure S4). Due to the difference of dynamic viscosity between μ1 and μ2, the ratio of the flow rate of the two fluids was changed to ensure that the interface of laminar flow was at the middle of the channel (Figure S4).
In Figure 3A, the numerical simulation demonstrates that the acoustic streaming in our device is able to mix highly viscous PEGDA700 polymers. The speed of sound, compressibility of the fluid, and the density for PEGDA700 solution is approximately 1,603 m/s, 3.47×10–10 Pa−1, and 1,120 kg/m3, respectively.65,66 Meanwhile, PEGDA700 is considered as an incompressible fluid in the simulation model. This prediction is confirmed by the concentration profile of unmixed and mixed PEGDA700 solutions in Figure 3B. Figure 3C shows the mixing indexes for eight various PEG700-water solutions (18.3–95.9 mPa.s). For all PEGDA700 solutions, the mixing index is below 0.1, indicating complete mixing. These results confirm the capability of our acoustofluidic device to mix highly viscous polymer solutions. Thus, our device is strong enough to synthesize nanoparticles from polymer precursors with high molecular weight and high concentration.
Fig. 3.
Numerical simulation and experimental results for mixing investigation of viscous PEGDA700 polymer solution in our acoustofluidic mixing devices. (A) Numerical simulations of PEGDA700 concentration profile for unmixed 18.3 mPa.s flow, mixed 18.3 mPa.s flow, and mixed 41.7 mPa.s flow, respectively. (B) Experimental results showing the mixed performance from acoustics off to acoustics on, where μ1 is kept at 18.3 mPa.s and μ2 is varied. When the acoustics are off, laminar flow is observed with a μ2 of 18.3 mPa.s. When the acoustics are on, fluid μ1 is completely mixed with μ2 at 18.3 and 41.7 mPa.s, respectively. Scale bar: 200 μm. (C) Plot of mixing indexes for mixed PEGDA700 solutions versus varying viscosities of μ2.
Size-Controllable Synthesis of High-Molecular-Weight PLGA-PEG Nanoparticles
Our acoustofluidic devices’ ability to perform complete and ultrafast solvent exchange can help prevent polymer aggregation. To test its effectiveness, we used the acoustofluidic devices to synthesize PLGA-PEG nanoparticles from different polymer precursors, including those with high molecular weights and high concentrations. Currently, three major stages are believed to be involved in the synthesis of PLGA-PEG nanoparticles by nanoprecipitation.28,67,68 First, after solvent exchange, hydrophobic PLGA chains precipitate from the surrounding water molecules by excluding them into certain ordered orientations, and disperse as unimers in the solvent mixture. Second, to increase the system entropy and minimize the orientations, neighboring unimers attract each other through PLGA chains and arrange into ordered oligomers (nuclei). The third stage is the diffusion-dominated addition of more unimers on nuclei. This process eventually terminates in the formation of kinetically locked PLGA-PEG nanoparticles, where the hydrophilic PEG groups on the nanoparticle surface shield their PLGA hydrophobic chains from the surrounding polar aqueous phase.3
Based on the three stages, Figure 4A provides a hypothesis to illustrate the discrepancy between PLGA-PEG nanoprecipitation in 2D HFF and the acoustofluidic devices. For 2D HFF, the precipitated polymers are highly concentrated at a narrow region, thus pushing high-molecular-weight polymers close enough to each other (first stage in Figure 4A). Then, the chances for forming nuclei site are significantly enhanced, and many nuclei sites can be generated on one hydrophobic PLGA chain, resulting in polymer aggregates like dendrimers (second stage). Finally, these dendrimers connect to each other and lead to three-dimensional polymer aggregate network (three stage). Consequently, neighboring unimers fail to self-assemble into spherical nanoparticles, and the hydrophilic PEG chains cannot completely shield PLGA chains from aqueous phase. In contrast, the acoustofluidic devices uniformly disperse PLGA-PEG unimers within the entire channel, increasing the inter-distance between unimers (first stage in Figure 4A). In the second stage, the dispersed unimers are able to arrange into spherical form due to its uniform dispersion and generate homogenous nuclei at the same timescale enabled by the ultrafast mixing. In the third stage, due to the homogenous dispersion of dispersed unimers and nuclei, the probability of adding unimers into nuclei is approximately equal, forming monodisperse PLGA-PEG nanoparticles. The hydrophilic PEG on the NP surface can then prevent the aggregation of nanoparticles and the adsorption of hydrophobic PLGA on PDMS microchannel walls.3,50,51
Fig. 4.
Acoustofluidic synthesis of high molecular weight polymeric nanoparticles without aggregation. (A) Schematic hypothesis illustrating the occurrence of polymer aggregation in the 2D HFF device and the absence of polymer aggregation in the acoustofluidic device. (B) The influence of polymer concentration on aggregation using the 2D HFF device from 0.01 mg/mL to 1 mg/mL PLGA (5K-10K). All microscopy images were captured at 1 min of operation. (C) Representative microchannel images showing the macroscopic nanoprecipitation evolution of PLGA50K-PEG5K at 50 mg/mL by 2D HFF and acoustofluidic devices. The microscopic images are taken at different time scale: left (1 min), middle (3 min) and right (6 min).
We then experimentally investigated the two fundamental mechanisms, i.e., PEG chains and uniform-dispersed polymers (low polymer concentration), in preventing polymer aggregation within a 2D HFF and acoustofluidic microchannel (Figure 4B). For comparison, we constructed acoustofluidic devices with polymer solution flowing in the middle of the microchannel as 2D HFF devices. The mixing time (τmix) for 2D HFF is estimated by Equation 3.28
| (3) |
Here, wf is the width of focusing region, D is the diffusivity of solvent, w is the width of microchannel, and R is the total flow rate ratio of water to polymer. To decrease mixing time, we chose the flow rate ratio of water, polymer, and water to be 50:1:50. For D =10−9 m2/s, R=100, and w=600 μm, the focusing width and mixing time are calculated to be around 4 μm and 4 ms, respectively, where the mixing time is small enough to generate homogenous nanoparticles.27,29 Compared to the 4 μm synthesis width, the 600 μm acoustofluidic microchannel decreases polymer concentration almost 150 times. Figure 4B shows that decreasing concentration can evidently alleviate PLGA aggregation in 2D HFF device. At the same polymer flow rate of 1 μL/min and a flow rate ratio of 10:1 at 8 VPP, the acoustofluidic devices prevent polymer aggregation through concentrations ranging from 0.01 mg/mL to 1 mg/mL. For PEG chains, despite the occurrence of aggregation at 1 mg/mL PLGA (5–10K), aggregation disappears at 10 mg/mL PLGA10k-PEG5k (Figure S5). These results indicate the effectiveness of hydrophilic PEG and uniform dispersion in preventing aggregation.3,50,51
Figure 4C compares the macroscopic evolution of polymer aggregation within the microchannel using the acoustofluidic and 2D HFF devices for PLGA50K-PEG5K at 50 mg/mL. In 2D HFF, the flow rate ratio was still kept as 50:1:50, while this ratio was set to 15:3:15 for the acoustofluidic device to keep at a flow rate ratio of 10:1. When comparing nanoprecipitation, we found that the acoustofluidic device can successfully prevent polymer aggregation while such aggregation occurred quickly within 2D HFF microchannel (Figure 4C). At 1 min, slight polymer aggregation appeared at the interfacial region between aqueous sheath streams (2D HFF in Figure 4C). This event further accumulated from 1 min to 6 min and restricted the mobility of polymers, resulting in device fouling. When the concentration of PLGA50k-PEG5k was increased to 90 mg/mL in 2D HFF, microscale polymer fibers were observed both in the microchannel interior and on the microchannel wall in less than 10 s of operation (Figure S6). This observation suggests that aggregation can occur not only between hydrophobic PLGA and PDMS, but also between hydrophobic PLGA molecules themselves.
After validating the macroscopic elimination of polymer aggregation, we then compared the size and monodispersity of the synthesized nanoparticles. In Figure S7, we first measured the mixing time of water, 30 mg/mL PLGA50K-PEG5K, and water at a flow rate of 25, 5, and 25 μL/min, respectively. The mixing time is observed to be less than 3 ms, indicating an ultrafast, complete mixing (Video S3). Figure 5A shows the schematic of the acoustofluidic device with high-molecular-weight PLGA-PEG injected in the middle of the microchannel. Figure 5B is the TEM image of the acoustofluidic synthesized nanoparticles from PLGA90K-PEG10K at 50 mg/mL, where the PEG shell layers are clearly observed and represented by the red arrows. This successful assembly preserves the nanoparticle structure of PLGA core and PEG shell layer. In Figure 5C, polymer aggregation is prevented within the acoustofluidic microchannel, which is consistent with the construction of hydrophilic PEG shell layer on PLGA cores in Figure 5B. Figure 5D shows the average size and size distributions of PLGA50K-PEG5K nanoparticles and PLGA90K-PEG10K nanoparticles at different concentrations yielded by 2D HFF, bulk vortexing method, and the acoustofluidic devices. The driving voltage is kept at 38 VPP. At PLGA50K-PEG5K 10 mg/ml, the flow rates were 25 μL/min, 10 μL/min, and 25 μL/min for water, polymer and water stream, respectively. At high concentration and molecular weight, the flow rate is 25, 5, and 25 μL/min for water, polymer and water stream, except for PLGA50K-PEG5K at 50 mg/mL (15, 3, and 15 μL/min). For PLGA50K-PEG5K, three polymer concentrations (10, 30, and 50 mg/mL) were applied because at 90 mg/mL the microchannel is blocked immediately (Figure S6). For PLGA90K-PEG10K, polymer precursors with higher concentrations (10, 50, and 90 mg/mL) were applied since the longer hydrophilic PEG chains (10 K) could better prevent hydrophobic PLGA aggregation. The acoustofluidic synthesis platform consistently generated nanoparticles with the narrowest dispersity and the smallest size and size variation among different measurements. In contrast, bulk and 2D HFF methods yielded nanoparticles with distinctly larger sizes and size variations, that is, poor reproducibility (Figure 5D and Figure S8). Especially for PLGA50K-PEG5K at 50 mg/mL, both 2D HFF and bulk methods were unable to produce nanoparticles owing to aggregation (indicated by X, Figure 4C, and 5D). These results demonstrate that the acoustofluidic synthesis platform allows the size-tunable synthesis of homogenous PLGA-PEG nanoparticles from high molecular weight polymers.
Fig. 5.
Size-tunable synthesis of PLGA-PEG nanoparticles from high-molecular-weight polymers. (A) Schematic of acoustofluidic device with high-molecular-weight PLGA-PEG injected in the middle of microchannel. (B) TEM image of acoustofluidic synthesized nanoparticles from PLGA90K-PEG10K at 50 mg/mL. The red arrows refer to the PEG shell layers. Scale bar: 100 nm. (C) Comparison of polymer aggregation of PLGA90K-PEG10K at 50 mg/mL within 2D HFF and acoustofluidic microchannel. Scale bar: 200 μm. (D) The dependence of nanoparticle sizes and size distributions of synthesized nanoparticles from PLGA50K-PEG5K and PLGA90K-PEG10K on polymer concentration, as well as the synthesis method. Here, X represents the failure of nanoparticle generation and # refers to the occurrence of polymer aggregation.
Sequential Nanoprecipitation for Core-Shell Nanoparticle Synthesis
Sequential nanoprecipitation for hierarchical nanoparticles preparation enables the development of novel multifunctional nanomedical systems. Specifically, PLGA-lipid nanoparticles can entrap hydrophilic agents in lipid shells and hydrophobic agents in PLGA cores.69 Chitosan/Eudragit core-shell nanoparticles can release therapeutic molecules in the targeted PH environment.5 However, the current 3D microfluidic devices for sequential nanoprecipitation requires precise coaxial control6 and the 2D devices complicate the intermediate procedures by using two separate devices.5 Here, we demonstrate a two-step sequential nanoprecipitation for core-shell PLGA70K-PEG2K/lipid nanoparticle synthesis with high molecular weights.
Figure 6A shows the two-step nanoprecipitation for generating core-shell PLGA70K-PEG2K/lipid nanoparticles. In the first stage, the PLGA70K-PEG2K solution is completely mixed within a water solution, forming the PLGA polymer core with few PEG chains extending into the water molecules. In the second stage, the polymer core solution is mixed again within a lipid solution. Due to the high ratio of PLGA to PEG (35:1), the majority of the surface area of the PLGA cores remains uncovered and exposed.47 The small amount of PEG (2 kDa) is utilized to prevent aggregation between the high-molecular-weight PLGA molecules (70 kDa). Eventually, under the hydrophobic attraction between the PLGA and the lipid,46,47 lipid molecules are assembled on the surface of the PLGA cores (Figure 6A). To ensure that the synthesized nanoparticles are hybrid particles rather than a combination of liposomes and PLGA nanoparticles, different polymer components were used, such as PLGA-PEG alone, lipid (DPPC/DSPE-PEG) alone, or a combination of both. A sufficient coverage of lipid on a PLGA core would prevent aggregation of PLGA NPs in PBS.69 Size stability of nanoparticles was analyzed in water and PBS as the lipid coverage changes by dynamic light scattering (Figure 6B). In Figure 6B, PLGA70K-PEG2K nanoparticles suffer from a dramatic increase in size from water to PBS, revealing a strong aggregation between uncovered polymer cores. Liposome nanoparticles only show a slight increase, exhibiting a favorable stability. By decreasing the PLGA70K-PEG2K/lipid ratio from 3:1 to 3:7, the hybrid PLGA70K-PEG2K/lipid nanoparticles stabilize in both water and PBS. The size increase in the case of 3:1 PLGA to lipid indicates that there is not enough lipid layer to further prevent the aggregation of PLGA70K-PEG2K NPs in water, and the addition of lipid layers leads to an increase in NP size. In Figure 6C, a single volume peak rather than a double peak is observed in the size distribution of PLGA70K-PEG2K/lipid with a ratio of 3:3 and 3:7. This further confirms the hybrid core-shell nanoparticles structure. The core-shell structure of PLGA70K-PEG2K/lipid was then revealed by TEM imaging (Figure 6D), while its counterpart of PLGA70K-PEG2K displays strong aggregation phenomenon and the absence of a shell layer (Figure 6E). These results suggest that lipid molecules are assembled on the PLGA core and that the acoustofluidic device is capable of conducting sequential nanoprecipitation.
Fig. 6.
Sequential nanoprecipitation for core-shell PLGA70K-PEG2K/lipid nanoparticles synthesis. (A) Microscopic images showing the solvent exchange of PLGA-PEG solution with water solution in the first stage at the beginning of the sharp-edges, and the mixing of PLGA core solution with lipid solution in the second stage in the middle of the sharp-edges. Scale bar: 200 μm. (B) Determination of lipid coverage on PLGA70K-PEG2K NPs. As the ratio of PLGA to lipid increases, size of the hybrid PLGA70K-PEG2K/lipid is decreased. (C) Size distributions in PBS and water with the variation in the ratio of PLGA to lipid. Complete coverage of lipid on PLGA core is observed at a PLGA to lipid ratio of 3:7. Below this ratio, the inadequate lipid coverage leads to aggregated NPs in PBS. (D) TEM image of core-shell PLGA70K-PEG2K/lipid nanoparticles. Scale bar: 50 nm. (E) TEM imaging of polymer aggregation of PLGA70K-PEG2K nanoparticles. Scale bar: 50 nm.
Conclusions
We present an acoustofluidic platform to synthesize nanoparticles from high-molecular-weight polymers in a size and structure-controlled manner. By systematically evaluating the influence of device configuration parameters, the acoustofluidic devices are fine-tuned to achieve micromixing in the entire microchannel with a timescale down to 2–3 ms. The ability to perform ultrafast, complete mixing enables our acoustofluidic platform to synthesize reproducible PLGA-PEG nanoparticles with high polymer precursor molecular weight and concentrations that previously was not possible with bulk mixing or most microfluidic approaches. The underlying mechanism results from diminished polymer interaction by uniform dispersion. Nanoparticles produced by our acoustofluidic platform exhibited favorable monodispersity and smaller nanoparticle diameter relative to 2D HFF or bulk methods.
Additionally, this device provides a new method for sequential self-assembly in a single device within a 2D structure. The core/shell PLGA-PEG/lipid nanoparticles were prepared by the formation of PLGA core in the first stage and the coverage of a lipid layer in the second stage. As each sharp-edge structure acts as an active mixing site, three or four sequential nanoprecipitation steps could be achieved in the future for multi-layer nanoparticle self-assembly. These synthesis abilities are especially desired for novel multifunctional therapeutic nanosystems. With its simple 2D structure and complete, ultrafast mixing nature, our acoustofluidic-based synthesis platform can harness the benefits of microfluidics in material synthesis to a broad set of scenarios, especially in applications where high-molecular-weight polymer, viscous polymers, or multiple polymer precursors are needed.
Supplementary Material
Acknowledgements
The authors gratefully acknowledge financial support from the National Institutes of Health (UG3TR002978, R01GM135486, and R01HD086325) and the United States Army Medical Research Acquisition Activity (W81XWH-18-1-0242). Shuaiguo Zhao acknowledges the financial support from the China Scholarship Council.
Footnotes
Conflicts of interest
T. J. H. has co-founded a start-up company, Ascent Bio-Nano Technologies Inc., to commercialize technologies involving acoustofluidics and acoustic tweezers.
Electronic Supplementary Information (ESI) available. See DOI: 10.1039/x0xx00000x
References
- 1.Valencia PM, Pridgen EM, Rhee M, Langer R, Farokhzad OC and Karnik R, ACS Nano, 2013, 7, 10671–10680. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 2.Lou D, Lu X, Zhang M, Bai M and Jiang J, Chem. Commun, 2018, 54, 6987–6990. [DOI] [PubMed] [Google Scholar]
- 3.Avgoustakis K, Curr. Drug Del, 2004, 1, 321–333. [DOI] [PubMed] [Google Scholar]
- 4.Rhee M, Valencia PM, Rodriguez MI, Langer R, Farokhzad OC and Karnik R, Adv. Mater, 2011, 23, 79–83. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 5.Hasani-Sadrabadi MM, Taranejoo S, Dashtimoghadam E, Bahlakeh G, Majedi FS, VanDersarl JJ, Janmaleki M, Sharifi F, Bertsch A, Hourigan K, Tayebi L, Renaud P, and Jacob KI, Adv. Mater, 2016, 28, 4134–4141. [DOI] [PubMed] [Google Scholar]
- 6.Liu D, Zhang H, Cito S, Fan J, Mäkilä E, Salonen J, Hirvonen J, Sikanen TM, Weitz DA and Santos H. l. A., Nano Lett, 2017, 17, 606–614. [DOI] [PubMed] [Google Scholar]
- 7.Bertrand N, Grenier P, Mahmoudi M, Lima EM, Appel EA, Dormont F, Lim J-M, Karnik R, Langer R and Farokhzad OC, Nat. Commun, 2017, 8, 1–8. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 8.Govender T, Riley T, Ehtezazi T, Garnett MC, Stolnik S, Illum L and Davis SS, Int. J. Pharm, 2000, 199, 95–110. [DOI] [PubMed] [Google Scholar]
- 9.Yang J, Guo Y, Lu C, Zhang R, Wang Y, Luo L, Zhang Y, Chu CH, Wang KJ, Obbad S, Yan W and Li X, Oncogene, 2019, 38, 4700–4714. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 10.Changalvaie B, Han S, Moaseri E, Scaletti F, Truong L, Caplan R, Cao A, Bouchard R, Truskett TM, Sokolov KV and Johnston KP, ACS Appl. Mater. Interfaces, 2019, 11, 46437–46450. [DOI] [PubMed] [Google Scholar]
- 11.Min Y, Roche KC, Tian S, Eblan MJ, McKinnon KP, Caster JM, Chai S, Herring LE, Zhang L, Zhang T, DeSimone JM, Tepper JE, Vincent BG, Serody JS and Wang AZ, Nat. Nanotechnol, 2017, 12, 877–882. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 12.Paka GD and Ramassamy C, Mol. Pharm, 2017, 14, 93–106. [DOI] [PubMed] [Google Scholar]
- 13.Xu X, Xie K, Zhang X-Q, Pridgen EM, Park GY, Cui DS, Shi J, Wu J, Kantoff PW, Lippard SJ, Langer R, Walker GC and Farokhzad OC, Proc. Natl. Acad. Sci. U. S. A, 2013, 110, 18638–18643. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 14.Hasan W, Chu K, Gullapalli A, Dunn SS, Enlow EM, Luft JC, Tian S, Napier ME, Pohlhaus PD, Rolland JP and DeSimone JM, Nano Lett., 2012, 12, 287–292. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 15.Zhao X, Bian F, Sun L, Cai L, Li L and Zhao Y, Small, 2020, 16, 1901943. [DOI] [PubMed] [Google Scholar]
- 16.Zhang H, Zhu Y and Shen Y, Small, 2018, 14, 1800360. [DOI] [PubMed] [Google Scholar]
- 17.Reboud J, Bourquin Y, Wilson R, Pall GS, Jiwaji M, Pitt AR, Graham A, Waters AP and Cooper JM, Proc. Natl. Acad. Sci. U. S. A, 2012, 109, 15162–15167. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 18.Friend J and Yeo LY, Rev. Mod. Phys, 2011, 83, 647. [Google Scholar]
- 19.Ahmed H, Destgeer G, Park J, Jung JH and Sung HJ, Adv. Sci, 2018, 5, 1700285. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 20.Li P and Huang TJ, Anal. Chem, 2018, 91, 757–767. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 21.Xie Y, Bachman H and Huang TJ, TrAC, Trends Anal. Chem, 2019, 117, 280–290. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 22.Connacher W, Zhang N, Huang A, Mei J, Zhang S, Gopesh T and Friend J, Lab Chip, 2018, 18, 1952–1996. [DOI] [PubMed] [Google Scholar]
- 23.Zhou Y, Wang H, Ma Z, Yang JK and Ai Y, Adv. Mater. Technol, 2020, 5, 2000323. [Google Scholar]
- 24.Chen B, Wu Y, Ao Z, Cai H, Nunez A, Liu Y, Foley J, Nephew K, Lu X and Guo F, Lab Chip, 2019, 19, 1755–1763. [DOI] [PubMed] [Google Scholar]
- 25.Schmid L, Weitz DA and Franke T, Lab Chip, 2014, 14, 3710–3718. [DOI] [PubMed] [Google Scholar]
- 26.Zhao S, Wu M, Yang S, Wu Y, Gu Y, Chen C, Ye J, Xie Z, Tian Z, Bachman H, Huang P-H, Xia J, Zhang P, Zhang H and Huang TJ, Lab Chip, 2020, 20, 1298–1308. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 27.Le NHA, Deng H, Devendran C, Akhtar N, Ma X, Pouton C, Chan H-K, Neild A and Alan T, Lab Chip, 2020, 20, 582–591. [DOI] [PubMed] [Google Scholar]
- 28.Karnik R, Gu F, Basto P, Cannizzaro C, Dean L, Kyei-Manu W, Langer R and Farokhzad OC, Nano Lett, 2008, 8, 2906–2912. [DOI] [PubMed] [Google Scholar]
- 29.Huang PH, Zhao S, Bachman H, Nama N, Li Z, Chen C, Yang S, Wu M, Zhang SP and Huang TJ, Adv. Sci, 2019, 6, 1900913. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 30.Jahn A, Stravis SM, Hong JS, Vreeland WN, Devoe DL and Gaitan M, ACS Nano, 2010, 4, 2077–2087. [DOI] [PubMed] [Google Scholar]
- 31.Rasouli MR and Tabrizian M, Lab Chip, 2019, 19, 3316–3325. [DOI] [PubMed] [Google Scholar]
- 32.Pessoa AC, Sipoli CC and Lucimara G, Lab Chip, 2017, 17, 2281–2293. [DOI] [PubMed] [Google Scholar]
- 33.Augustsson P, Karlsen JT, Su H-W, Bruus H and Voldman J, Nat. Commun, 2016, 7, 1–9. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 34.Olofsson K, Carannante V, Ohlin M, Frisk T, Kushiro K, Takai M, Lundqvist A, Önfelt B and Wiklund M, Lab Chip, 2018, 18, 2466–2476. [DOI] [PubMed] [Google Scholar]
- 35.Tian L, Martin N, Bassindale PG, Patil AJ, Li M, Barnes A, Drinkwater BW and Mann S, Nat. Commun, 2016, 7, 1–10. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 36.Cushing K, Undvall E, Ceder Y, Lilja H and Laurell T, Anal. Chim. Acta, 2018, 1000, 256–264. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 37.Collins DJ, Morahan B, Garcia-Bustos J, Doerig C, Plebanski M and Neild A, Nat. Commun, 2015, 6, 1–11. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 38.Biroun MH, Li J, Tao R, Rahmati M, McHale G, Dong L, Jangi M, Torun H and Fu Y, Phys. Rev. Appl, 2020, 14, 024029. [Google Scholar]
- 39.Hsu MN, Wei SC, Guo S, Phan DT, Zhang Y and Chen CH, Small, 2018, 14, 1802918. [DOI] [PubMed] [Google Scholar]
- 40.Tao R, McHale G, Reboud J, Cooper JM, Torun H, Luo J, Luo J, Yang X, Zhou J and Canyelles-Pericas P, Wu Q and Fu Y, Nano Lett, 2020, 20, 3263–3270. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 41.Melde K, Choi E, Wu Z, Palagi S, Qiu T and Fischer P, Adv. Mater, 2018, 30, 1704507. [DOI] [PubMed] [Google Scholar]
- 42.Vladisavljević GT, Shahmohamadi H, Das DB, Ekanem EE, Tauanov Z and Sharma L, J. Colloid Interface Sci, 2014, 418, 163–170. [DOI] [PubMed] [Google Scholar]
- 43.Brzeziński M, Socka M and Kost B, Polym. Int, 2019, 68, 997–1014. [Google Scholar]
- 44.Huang P-H, Xie Y, Ahmed D, Rufo J, Nama N, Chen Y, Chan CY and Huang TJ, Lab Chip, 2013, 13, 3847–3852. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 45.Zhao S, He W, Ma Z, Liu P, Huang P-H, Bachman H, Wang L, Yang S, Tian Z, Wang Z, Gu Y, Xie Z and Huang TJ, Lab Chip, 2019, 19, 941–947. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 46.Thevenot J, Troutier A-L, Putaux J-L, Delair T and Ladaviere C, J. Phys. Chem. B, 2008, 112, 13812–13822. [DOI] [PubMed] [Google Scholar]
- 47.Griffiths PC, Cattoz B, Ibrahim MS and Anuonye JC, Eur. J. Pharm. Biopharm, 2015, 97, 218–222. [DOI] [PubMed] [Google Scholar]
- 48.Bachman H, Huang P-H, Zhao S, Yang S, Zhang P, Fu H and Huang TJ, Lab Chip, 2018, 18, 433–441. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 49.Lei J, Hill M and Glynne-Jones P, Lab Chip, 2014, 14, 532–541. [DOI] [PubMed] [Google Scholar]
- 50.Wang Z, Huang P-H, Chen C, Bachman H, Zhao S, Yang S and Huang TJ, Lab Chip, 2019, 19, 4021–4032. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 51.Jokerst JV, Lobovkina T, Zare RN and Gambhir SS, Nanomedicine, 2011, 6, 715–728. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 52.Locatelli E and Franchini MC, J. Nanopart. Res, 2012, 14, 1316. [Google Scholar]
- 53.Su C, Xia Y, Sun J, Wang N, Zhu L, Chen T, Huang Y, and Liang D, Langmuir, 2014, 30, 6219–6227. [DOI] [PubMed] [Google Scholar]
- 54.Luginbuhl KM, Mozhdehi D, Dzuricky M, Yousefpour P, Huang FC, Mayne NR, Buehne KL, and Chilkoti A, Angew. Chem. Int. Ed. 2017, 56, 13979–13984. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 55.Feng X, Ren Y, Hou L, Tao Y, Jiang T, Li W and Jiang H, Lab Chip, 2019, 19, 2936–2946. [DOI] [PubMed] [Google Scholar]
- 56.Fu H, Liu X and Li S, RSC Adv, 2017, 7, 10906–10914. [Google Scholar]
- 57.Nama N, Huang P-H, Huang TJ and Costanzo F, Lab Chip, 2014, 14, 2824–2836. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 58.Kinsler LE; Frey AR; Coppens AB; Sanders JV, (4th Edition), Wiley-VCH; (1999). [Google Scholar]
- 59.Van Phan H, Coşkun MB, Şeşen M, Pandraud G, Neild A and Alan T, Lab Chip, 2015, 15, 4206–4216. [DOI] [PubMed] [Google Scholar]
- 60.Westerhausen C, Schnitzler LG, Wendel D, Krzysztoń R, Lächelt U, Wagner E, Rädler JO and Wixforth A, Micromachines, 2016, 7, 150. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 61.Lim J-M, Swami A, Gilson LM, Chopra S, Choi S, Wu J, Langer R, Karnik R and Farokhzad OC, ACS Nano, 2014, 8, 6056–6065. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 62.Nama N, Huang P-H, Huang TJ and Costanzo F, Biomicrofluidics, 2016, 10, 024124. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 63.Ozcelik A, Ahmed D, Xie Y, Nama N, Qu Z, Nawaz AA and Huang TJ, Anal. Chem, 2014, 86, 5083–5088. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 64.Labbaf S, Ghanbar H, Stride E and Edirisinghe M, Macromol. Rapid Commun, 2014, 35, 618–623. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 65.Nama N, Barnkob R, Mao Z, Kahler CJ, Costanzo F and Huang TJ, Lab Chip, 2015, 15, 2700–2709. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 66.Ophir J and Jaeger P, Ultrason. Imaging, 1982, 4, 163–170. [DOI] [PubMed] [Google Scholar]
- 67.Cui X, Mao S, Liu M, Yuan H and Du Y, Langmuir, 2008, 24, 10771–10775. [DOI] [PubMed] [Google Scholar]
- 68.Shields IV CW, Sun D, Johnson KA, Duval KA, Rodriguez AV, Gao L, Dayton PA and Lopez GP, Angew. Chem. Int. Ed, 2014, 53, 8070–8073. [DOI] [PubMed] [Google Scholar]
- 69.Valencia PM, Basto PA, Zhang L, Rhee M, Langer R, Farokhzad OC and Karnik R, ACS Nano, 2010, 4, 1671–1679. [DOI] [PMC free article] [PubMed] [Google Scholar]
Associated Data
This section collects any data citations, data availability statements, or supplementary materials included in this article.






