Accuracy of different methods for simulated reads with 12× coverage on chromosomes 21 and 22

Method DEL recall (%) INS recall (%) INV recall (%) DUP recall (%) TRA recall (%) Overall recall (%) FDR (%)
Baseline method 63.3 37.1 92 64 50 57.5 3
NGMLR-Sniffles 62.6 10.2 88 67 63 54.25 3.4
Most sensitive method 85.9 47.8 95 80 76.5 75.1 6.4
SVNN 84.1 46.2 95 77 76.5 73.8 4.6