Skip to main content
. 2021 Jun 22;135:104588. doi: 10.1016/j.compbiomed.2021.104588

Table 2.

Comparison of the proposed deep convolution network with other models in the COVID-19 CT dataset.

Method Sensitivity Specificity PPV NPV Precision
CNN 0.87 0.875 0.882 0.862 0.872
Loey M et al. [29] 0.78 0.88 0.83
Gifani P et al. [30] 0.85 0.86 0.86
Polsinelli M et al. [36] 0.88 0.82 0.85 0.85 0.85
Zhao J et al. [38] 0.89
Singh D et al. [359] 0.91 0.89 0.90 0.91 0.90
Parnian Afshar et al. [12] 0.90 0.96 0.96
He X et al. [37] 0.96
Bai H X et al. [39] 0.95 0.96 0.96
The proposed method 0.98 0.96 0.96 0.98 0.97