. 2021 Jun 18;59(7):e02942-20. doi: 10.1128/JCM.02942-20

TABLE 1.

Specifications of the KCDC IFA and four commercial kits from companies A to Da

Assay Type of assay Diagnostic criteria Detailed explanation Reference(s)
KCDC IFA Cutoff values of ≥1:16 for IgM and ≥1:256 for IgG; ≥4-fold increase in IgM or IgG titers Separate detection of IgM and IgG against 4 O. tsutsugamushi antigen strains (Gilliam, Karp, Kato, and Boryong) 3, 5
Company A IFA Cutoff value of ≥1:40 Detection of total immunoglobulins (IgM/IgG/IgA) against 3 O. tsutsugamushi antigen strains (Boryong, Karp, and Gilliam) 9
Company B IFA Cutoff values of ≥1:64 for IgM and ≥1:128 for IgG Separate detection of IgM and IgG against 4 O. tsutsugamushi antigen strains (Gilliam, Karp, Kato, and Boryong) 6
Company C RDT Positive or negative Detection of IgM/IgG against 5 O. tsutsugamushi antigen strains (Gilliam, Karp, Kato, Kangwon, and Boryong) 10
Company D RDT Positive or negative Detection of total immunoglobulins against 3 O. tsutsugamushi antigen strains (Gilliam, Karp, and Kato) 8, 10
a

KCDC, Korea Centers for Disease Control and Prevention; IFA, indirect immunofluorescence assay; RDT, immunochromatography-based rapid diagnostic test.