Table 1.

Details of antibody clones, format, staining platforms used and their recommended concentrations for IHC protocol.

Antibody Clone Format Staining Platform Recommended
Concentrations
30-9 Ready-to-Use Manual, Leica Bond autostainer, Ventana autostainer  
MIB1 Concentrate Manual, Leica Bond autostainer 1:75-1:150 (1:100 was used)
MM1 Concentrate Manual, Leica Bond autostainer (1:200)
SP6 Concentrate Manual, Leica Bond autostainer (1:200)
8D5 Concentrate Manual, Leica Bond autostainer (1:400)
1297A Concentrate Manual, Leica Bond autostainer 3-15 μg/mL (3μg/1:33 was used)