Skip to main content
. Author manuscript; available in PMC: 2022 Jun 25.
Published in final edited form as: Circ Res. 2021 Apr 23;129(1):50–62. doi: 10.1161/CIRCRESAHA.120.317532

Table 1.

Echocardiography in control & mutant sPRR mice at baseline and following 12-days of Ang-II infusion.

Baseline Post-Ang-II
Control (N=8) Mutant (N=9) Control (N=6) Mutant (N=8)
Heart rate (bpm) 365 ± 9 339 ± 13 361 ± 18 359 ± 12
Cardiac output (ml/min/g) 0.4 ± 0.02 0.4 ± 0.02 0.3 ± 0.05 0.4 ± 0.03
Ejection fraction (%) 47.1 ± 2.6 45.6 ± 1.9 44.9 ± 5.9 48.6 ± 2.8
Fractional shortening (%) 23.8 ± 3.5 22.3 ± 1.0 22.4 ± 3.5 24.2 ± 1.6
Left ventricular mass (mg/g) 2.9 ± 0.1 3.3 ± 0.2 * 3.0 ± 0.1 3.3 ± 0.1
Stroke volume (μl/g) 1.0 ± 0.04 1.0 ± 0.07 0.9 ± 0.09 1.1 ± 0.06 *
Volume (end-diastolic, μl/g) 2.2 ± 0.2 2.3 ± 0.2 2.0 ± 0.09 2.3 ± 0.09 *
Volume (end-systolic, μl/g) 1.2 ± 0.2 1.2 ± 0.1 1.1 ± 0.2 1.2 ± 0.1
E/A 1.8 ± 0.1 1.5 ± 0.1 2.0 ± 0.3 1.7 ± 0.1
*

P <0.05 vs control mice by Student’s unpaired t-test.