Skip to main content
. 2021 Jun 9;11(6):536. doi: 10.3390/jpm11060536

Table 2.

Individual test session responses per protocol—behavioral and EEG responder.

Subject Behavioral Responder Alpha (8–12.5 Hz)/Gamma (30.5–44 Hz)
1 1 Hz 10 Hz 20 Hz 1 Hz 10 Hz 20 Hz
Left 12.86 - - Left - ↓ γ ↑ α ↓ γ
Right 17.15 - - Right - ↓ γ -
2 - 1 Hz 10 Hz 20 Hz
Left ↑ α ↓ γ ↑ α ↓ γ -
Right - - -
3 1 Hz 10 Hz 20 Hz 1 Hz 10 Hz 20 Hz
Left 3.98 - 3.71 Left ↑ α ↓ γ ↑ α -
Right - - - Right ↓ γ - -
4 1 Hz 10 Hz 20 Hz 1 Hz 10 Hz 20 Hz
Left - 10.35 - Left ↑ α ↓ γ - -
Right - 9.28 25.71 Right - - -
5 1 Hz 10 Hz 20 Hz 1 Hz 10 Hz 20 Hz
Left - 16.42 - Left ↑ α ↓ γ ↑ α
Right 10 16.79 21.42 Right - - -
6 1 Hz 10 Hz 20 Hz 1 Hz 10 Hz 20 Hz
Left - 10.71 - Left ↑ α - ↑ α
Right - - - Right - ↑ α ↓ γ -
7 - 1 Hz 10 Hz 20 Hz
Left - ↑ α -
Right - ↑ α ↑ α ↓ γ
8 1 Hz 10 Hz 20 Hz 1 Hz 10 Hz 20 Hz
Left - 6.07 8.93 Left - ↑ α ↓ γ ↓ γ
Right - 4.64 9.28 Right - ↑ α -
9 1 Hz 10 Hz 20 Hz 1 Hz 10 Hz 20 Hz
Left - - 3.93 Left ↑ α ↓ γ ↑ α ↓ γ ↑ α ↓ γ
Right 7.55 - - Right ↓ γ - -
10 1 Hz 10 Hz 20 Hz 1 Hz 10 Hz 20 Hz
Left 15.36 - 5.71 Left ↓ γ ↑ α ↓ γ
Right - - - Right - ↓ γ ↑ α ↓ γ
11 - 1 Hz 10 Hz 20 Hz
Left ↑ α - -
Right ↓ γ ↑ α ↓ γ ↑ α
12 - 1 Hz 10 Hz 20 Hz
Left - - -
Right - ↑ α ↓ γ
13 - 1 Hz 10 Hz 20 Hz
Left ↓ γ ↑ α ↓ γ -
Right ↑ α ↓ γ ↓ γ -
14 - 1 Hz 10 Hz 20 Hz
Left ↑ α ↓ γ ↑ α ↓ γ
Right ↓ γ - ↑ α
15 - 1 Hz 10 Hz 20 Hz
Left ↓ γ ↑ α -
Right ↓ γ - -
16 1 Hz 10 Hz 20 Hz 1 Hz 10 Hz 20 Hz
Left - 5 12.85 Left - ↑ α ↓ γ -
Right - - 10 Right - ↑ α ↓ γ
17 - 1 Hz 10 Hz 20 Hz
Left - ↓ γ -
Right ↑ α ↓ γ ↑ α ↓ γ
18 - 1 Hz 10 Hz 20 Hz
Left ↓ γ ↓ γ ↑ α ↓ γ
Right ↑ α ↓ γ ↑ α -
19 1 Hz 10 Hz 20 Hz 1 Hz 10 Hz 20 Hz
Left - 13.57 13.57 Left ↑ α ↓ γ -
Right - - - Right ↑ α ↓ γ ↑ α
20 - 1 Hz 10 Hz 20 Hz
Left ↓ γ ↓ γ -
Right - - -
21 1 Hz 10 Hz 20 Hz 1 Hz 10 Hz 20 Hz
Left - - - Left - - ↓ γ
Right 7.14 - 3.93 Right ↓ γ ↓ γ ↓ γ
22 1 Hz 10 Hz 20 Hz 1 Hz 10 Hz 20 Hz
Left - - 7.85 Left ↓ γ ↑ α ↓ γ -
Right - - - Right - - -

Note: Behavioral response was defined via a sham-superior tinnitus suppression on both test session days in at least one of the verum protocols. EEG response was defined as sham-superior alpha increases, respectively gamma decreases, in a minimum number of two neighboring electrodes on both test session days in at least one verum protocol. For behavioral responders, the mean tinnitus suppression (averaged over both test session days) is presented per rTMS protocol. Alpha increases (↑ α) and gamma decreases (↓ γ) are equally presented per subject and protocol. Dashes indicate no response.