Table 6.
Assay comparison with titer presentation of positive serum samples.
COVID-19 SIA |
Orient Gene Rapid Test * |
WANTAI ELISA |
|||
---|---|---|---|---|---|
Sample # | IgM | IgG | IgM | IgG | Total Ab |
1 | 1:2500 | 1:2500 | 1:50 | 1:10 | 1:6250 |
2 | 1:500 | 1:100 | 1:10 | 1:10 | 1:250 |
3 | 1:100 | 1:2500 | 1:1 | 1:10 | 1:250 |
4 | 1:2500 | ≥1:12,500 | 1:50 | 1:50 | 1:6250 |
5 | 1:2500 | 1:500 | 1:50 | 1:10 | 1:1250 |
6 | 1:100 | 1:12,500 | 1:10 | 1:10 | 1:250 |
7 | 1:12,500 | 1:12,500 | 1:50 | 1:50 | 1:6250 |
8 | 1:100 | 1:2500 | 1:10 | 1:10 | 1:50 |
9 | 1:2500 | 1:12,500 | 1:10 | 1:10 | 1:6250 |
10 | 1:12,500 | 1:12,500 | 1:50 | 1:50 | 1:6250 |
11 | 1:62,500 | 1:12,500 | 1:50 | 1:50 | 1:6250 |
Ig, immunoglobulin; Ab, antibodies; COVID-19, Coronavirus disease 2019; SIA, suspension immunoassay; * Additional 1:17 dilution (5 μL serum and 80 μL buffer during analysis). # Study seropositivity = 26.6% (76/286); #, number.