Table 3.

Comparison of characteristics of cavitation methods (NIC, AIC, LIC, and drop-tower test) [38]. This table is modified from [38] with additional information.

NIC AIC LIC Drop Tower Test
Driving force Pressure energy Wave energy Potential energy
Strain rate 10−4–103 103–108 101–108 100–105
Scale (µm) 100–105 103 10−1–102 102–105
Pressure (Pa) ≤105 ≤107 ≤108 ≤106
Cavity type Single Multiple Single and Multiple Single and Multiple
Level of accessibility Low High High Intermediate
Approach type Contact Noncontact Noncontact Noncontact
Thermal effect Low Intermediate High Low
Application Drug delivery Lithotripsy
Imaging,
Drug delivery
Drug delivery,
Microsurgery,
Medical diagnostic,
High strain rate material properties
High strain rate material properties (Isothermal)