Skip to main content
. 2021 Jun 10;11(6):1071. doi: 10.3390/diagnostics11061071

Table 9.

Evaluation Results with the CN vs. EMCI Binary Classification.

Reference Methodology Accuracy (%) Sensitivity (%) Specificity (%)
[37] Vgg16 85.16 84.29 85.98
[23] Graph CNN 85.42 86.57 84.42
[39] CNN 93.96 90.46 98.19
[35] Deep 3D CNN 59 - -
Proposed Model Modified ResNet18 98.74 97.24 100