Table 2.
Ref. | #Sen | Method | #Sub | System Accuracy (%) |
Drinking Detection Accuracy (%) |
Weight Error/ Accuracy |
Limitations |
---|---|---|---|---|---|---|---|
[87] | 9+ | Rule-based, template matching | 3 | 80 | - | 82.62% accuracy |
Small sample size, all objects need RFID |
[89] | 1264 | DT 1, 7-class No LOSO 2 |
5 | 91 | 99 | 16% RMSE | Low weight accuracy |
With LOSO 2 | 76 | 99 | |||||
[91] | 1 | Segmentation and thresholding | 271 | 39% of bites are undetected |
39% of drink sips undetected |
- | Many false positives and undetected intakes |
[92] | 8 | Comparing against acoustic neck microphone | 2 | - | - | <9 g error | Small sample size |
1 Decision Tree, 2 Leave-one-subject-out