Basic characteristics of NBT-Pluronic F-127 gels with various concentrations of NBT and irradiated with UVA, UVB and UVC radiation.

The Range of UV Radiation Concentration of NBT [g/dm3] Dose Sensitivity
[cm2/J]
Intercept [−] Linear Dose Range
[J/cm2]
Dynamic Dose Range [J/cm2] Threshold Dose [J/cm2] R2
UVA 1 0.0554 ± 0.0008 0.0291 ± 0.0009 0–3 0.01–3 0.01 0.998
UVB 0.0691 ± 0.0014 0.0311 ± 0.0016 0–3 0.01–3 0.01 0.995
UVC 0.0068 ± 0.0005 0.0280 ± 0.0005 0.2–2 0.01–3 0.01 0.978
UVA 2 0.0592 ± 0.0008 0.0545 ± 0.0009 0–3 0.01–3 0.01 0.998
UVB 0.0719 ± 0.0016 0.0566 ± 0.0018 0–3 0.01–3 0.01 0.994
UVC 0.0059 ± 0.0001 0.0541 ± 0.0001 0.01–1.5 0.01–3 0.01 0.995
UVA 5 0.0730 ± 0.0010 0.1213 ± 0.0012 0–3 0.01–3 0.01 0.998
UVB 0.0930 ± 0.0027 0.1259 ± 0.0031 0–3 0.01–3 0.01 0.990
UVC 0.0077 ± 0.0003 0.1219 ± 0.0002 0.1–1.5 0.01–3 0.01 0.984