(A) Multiplex detection
of anti-Dig (blue) and cetuximab (orange)
antibodies using two orthogonal-responsive circuits releasing two
different reporter strands labeled with two non-interfering redox
labels (i.e., methylene blue, MB, and anthraquinone, AQ). (B) SWV
profiles achieved for different experiments performed in the absence
of both antibodies (left), in the presence of only one antibody (center),
and in the presence of both antibodies (right). The colored antibody
image identifies the added target for each experiment. The experiments
were performed in a 100 μL phosphate buffer (50 mM Na2HPO4, 150 mM NaCl, pH 7.0) solution containing the two
antibody-responsive circuits as previously described. The SWV voltammograms
were obtained at saturating concentrations of the target antibody
(300 nM).