Predictive performance of the two models in the training and validation cohorts

Radiomics model1 Radiomics nomogram model1
Training cohort Validation cohort Training cohort Validation cohort
AUC (95%CI) 0.848 (0.743–0.952) 0.795 (0.581–1.000) 0.902 (0.811–0.994) 0.877 (0.735–1.000)
Accuracy (%) 0.766 0.714 0.875 0.893
Sensitivity (%) 0.625 1.000 0.857 0.800
Specificity (%) 0.906 0.704 0.884 0.944
Positive predictive value (%) 0.870 0.111 0.783 0.889
Negative predictive value (%) 0.707 1.000 0.927 0.895