Clinical information and serology of ocrelizumab-treated group

Patient Sex Age (years) Disease duration (years) EDSS Vaccine Test method Antibody titer (U/ml) Titer cut-off (U/ml) Test result Time vaccine-test (days) WBC (× 109/l) Lymphocytes (× 109/l) CD20 count (%) Therapy duration (years) Therapy cycles Time vaccine-last dose (months) Previous IS
1 F 50.6 13.4 5.5 BNT162b2 ECLIA  < 0.40 0.80 Negative 37 5.76 0.99 0.00 1.3 2 4.8 Yes
2 F 30.8 6.8 1.0 BNT162b2 CMIA 2.80 50.00 Negative 33 NA NA NA 2.1 4 2.4 No
3 F 40.0 14.0 3.5 BNT162b2 CMIA 0.30 NA Negative 25 4.64 1.22 1.00 2.5 4 5.0 No
4 F 41.1 22.4 5.5 BNT162b2 DELFIA 21.00 1.20 Positive 61 NA NA NA 2.0 2 8.2 Yes
5 F 50.8 8.3 6.5 BNT162b2 ECLIA 98.50 0.80 Positive 19 6.37 1.60 11.10 3.4 5 5.4 Yes
6 M 57.1 8.4 5.0 BNT162b2 ECLIA 238.00 0.80 Positive 31 6.30 1.30 2.10 3.4 6 5.0 Yes
7 F 28.0 3.4 1.5 BNT162b2 CLIA 0.05 1.00 Negative 31 6.60 1.90 0.03 2.4 4 3.1 No
8 F 61.3 11.0 6.0 BNT162b2 ECLIA 0.11 1.10 Negative 34 5.28 2.35 0.10 3.2 6 5.8 No
9 F 46.6 26.0 6.5 BNT162b2 CLIA 0.07 10.00 Negative 66 NA NA NA 2.7 6 2.8 Yes
10 M 32.3 14.0 6.5 BNT162b2 ECLIA  < 0.40 0.80 Negative 30 9.20 2.20 0.00 2.5 5 5.0 No
11 M 23.0 6.1 2.5 mRNA-1273 ECLIA  < 0.40 0.80 Negative 42 6.50 2.30 0.50 2.9 5 4.6 No
12 F 56.3 1.3 4.5 BNT162b2 CLIA 65.90 15.00 Positive 19 4.20 1.60 0.50 0.0 1 3.5 No
13 M 43.4 4.3 4.5 BNT162b2 ECLIA  < 0.40 0.80 Negative 18 5.80 1.20 0.00 2.7 5 5.9 No
14 M 36.8 10.9 3.5 BNT162b2 ECLIA 22.40 0.80 Positive 21 5.49 1.18 0.03 2.1 4 5.9 No
15 F 64.1 19.5 3.0 BNT162b2 CMIA 155.00 33.80 Positive 21 3.96 1.12 0.04 2.1 4 5.5 Yes
16 M 43.2 25.2 4.0 BNT162b2 CMIA  < 2.20 22.00 Negative 28 4.33 1.14 0.03 2.2 4 4.2 Yes

WBC white blood cells count, IS immunosuppressants—i.e. cyclophosphamide, mitoxantrone, ECLIA electrochemiluminescence immunoassay, CLIA chemiluminescence immunoassay, CMIA chemiluminescence microparticle immunoassay, DELFIA dissociation-enhanced lanthanide fluorescent immunoassay