Performance comparison in terms of radiomics for data #1 (z-score normalization is active).

Data features Accuracy AUC Sensitivity Specificity G-mean Precision F-measure
FOS 97,92 98,44 100 96,88 98,43 94,12 96,97
GLCM 89,58 87,50 81,25 93,75 87,28 86,67 83,87
GLRLM 78,75 72,19 52,50 91,88 69,45 76,36 62,22
GLSZM 94,58 93,13 88,75 97,50 93,02 94,67 91,61
FOS + GLCM 95,42 94,38 91,25 97,50 94,32 94,81 92,99
FOS + GLRLM 97,50 98,13 100 96,25 98,11 93,02 96,39
FOS + GLSZM 96,67 97,19 98,75 95,63 97,17 91,86 95,18
GLCM + GLRLM 91,25 88,13 78,75 97,50 87,62 94,03 85,71
GLCM + GLSZM 94,58 94,69 95,00 94,38 94,69 89,41 92,12
GLRLM + GLSZM 96,67 96,25 95,00 97,50 96,24 95,00 95,00
FOS + GLCM + GLRLM 95,83 95,63 95,00 96,25 95,62 92,68 93,83
FOS + GLCM + GLSZM 96,25 94,69 90,00 99,38 94,57 98,63 94,12
FOS + GLRLM + GLSZM 98,75 99,06 100 98,13 99,06 96,39 98,16
GLCM + GLRLM + GLSZM 95,42 94,38 91,25 97,50 94,32 94,81 92,99
FOS + GLCM + GLRLM + GLSZM 94,58 94,69 95,00 94,38 94,69 89,41 92,12