Table 8.
Performance comparison in terms of radiomics for data #2 (minmax normalization is active).
| Data features/Success rates | Accuracy | AUC | Sensitivity | Specificity | G-mean | Precision | F-measure |
|---|---|---|---|---|---|---|---|
| FOS | 98,75 | 99,22 | 100 | 98,44 | 99,22 | 94,12 | 96,97 |
| GLCM | 93,75 | 87,66 | 77,50 | 97,81 | 87,07 | 89,86 | 83,22 |
| GLRLM | 86,75 | 70,63 | 43,75 | 97,50 | 65,31 | 81,40 | 56,91 |
| GLSZM | 95,00 | 91,25 | 85,00 | 97,50 | 91,04 | 89,47 | 87,18 |
| FOS GLCM | 98,25 | 97,03 | 95,00 | 99,06 | 97,01 | 96,20 | 95,60 |
| FOS GLRLM | 99,00 | 98,44 | 97,50 | 99,38 | 98,43 | 97,50 | 97,50 |
| FOS GLSZM | 98,00 | 96,88 | 95,00 | 98,75 | 96,86 | 95,00 | 95,00 |
| GLCM GLRLM | 94,25 | 90,31 | 83,75 | 96,88 | 90,07 | 87,01 | 85,35 |
| GLCM GLSZM | 95,25 | 92,81 | 88,75 | 96,88 | 92,72 | 87,65 | 88,20 |
| GLRLM GLSZM | 94,75 | 89,69 | 81,25 | 98,13 | 89,29 | 91,55 | 86,09 |
| FOS GLCM GLRLM | 97,75 | 95,31 | 91,25 | 99,38 | 95,23 | 97,33 | 94,19 |
| FOS GLCM GLSZM | 97,75 | 97,66 | 97,50 | 97,81 | 97,66 | 91,76 | 94,55 |
| FOS GLRLM GLSZM | 98,50 | 97,19 | 95,00 | 99,38 | 97,16 | 97,44 | 96,20 |
| GLCM GLRLM GLSZM | 94,50 | 89,53 | 81,25 | 97,81 | 89,15 | 90,28 | 85,53 |
| FOS GLCM GLRLM GLSZM | 97,50 | 95,16 | 91,25 | 99,06 | 95,08 | 96,05 | 93,59 |
(Optimum results are italicized and bolded for every feature combination.)