Skip to main content
. 2021 May 3;93(9):5339–5349. doi: 10.1002/jmv.27029

Table 3.

Frequency of SARS‐CoV‐2 detection in air samples collected at 01 and 03‐ m distance from COVID‐19 patients in medicine ward and ICU

Site of sample collection Distance from the patients No. sample collected SARS‐CoV‐2 positivity rate (%) C t Value (RdRp gene)
Medicine ward 1 m 06 6/6 (100%) 25.31
27.43
24.56
23.12
28.92
27.56
3 m 06 02/06 (33%) 34.32
33.09
ICU 1 m 06 06/06 (100%) 22.32
23.12
21.32
25.79
19.18
19.23
3 m 06 03/06 (50%) 24.54
23.00
21.76

Abbreviations: COVID‐19, coronavirus disease 2019; ICU, intensive care unit; SARS‐CoV‐2, severe acute respiratory syndrome coronavirus 2.