Table 2.

Diagnostic performance of the evaluated Ag‐RDTs according to time form the onset of symptoms

Time from the onset of symptoms Days Panbio SD‐Biosensor p value
7 days 4 (2 – 6) Positive samples 64/73 Positive samples 66/73 0.625
Sensitivity 87.7 Sensitivity 90.4
(n = 73)
(81.2 – 96.1)
(77.9– 94.2)
8–14 days 9 (8 – 11) Positive samples 13/42 Positive samples 16/42 0.250
Sensitivity 31.0 Sensitivity 38.1
(n = 42) (17.6– 47.1)
(23.6 – 54.4)
>14 days 16 (15 – 18) Positive samples 4/13 Positive samples 5/13 1.000
Sensitivity 30.8 Sensitivity 38.5
(n = 13)
(13.9 – 68.4)
(9.1 – 61.4)

Note: Statistics: sensitivity results are expressed as percentage with 95% CI. P‐values were calculated by the McNemar's test. No p‐value was statistically significant (p < 0.05).

Abbreviations: Ag‐RDT, antigen rapid diagnostic test; 95% CI, 95% confidence interval; p‐value, level of significance.