Published in final edited form as: J Acoust Soc Am. 2013 Apr;133(4):2490–2501. doi: 10.1121/1.4792935

Table I.

Parameters used for fast and slow wave amplitudes, attenuation coefficients, and velocities. Parameter values reported by Nelson et al. (2011) correspond to data from Nagatani et al. (2008). Parameter values for human calcaneus (right column) correspond to mean values from Hoffman et al. (2012), in which numerical values for mean vfast and vslow were reported numerically and estimates for mean values for Afast, Aslow, βfast, and βslow may be estimated from Figures 6 and 5 (Hoffman et al., 2012).

Reference Nelson et al., 2011, Nagatani et al., 2008 Anderson et al., 2010 Hoffman et al., 2012
Source Bovine femur Human femur Human calcaneus
Center frequency f0 (MHz) 1.0 0.5 0.5
Thickness (mm) 6,7,8,…,15 16.8 11.9
Afast 1.00 0.82 0.3
Aslow 0.13 0.23 0.6
βfast (dB/cmMHz) 49.2 42.8 4
βslow (dB/cmMHz) 7.1 5.2 4
vfast (ω0) (m/s) 1933 2036 1675
vslow (ω0) (m/s) 1475 1511 1527
Separation (theory) 0.38 – 0.95 0.56 0.13
Separation (numerical) 0.45 – 0.89 0.65 0.12
Frequency Analysis Range (MHz) (flowfhigh) 0.25 – 1.6 0.2 – 0.8 0.2 – 0.8