Table IV.

Means, standard deviations, and root-mean-square errors (RMSE) for parameter estimates from simulations with SNR = 40 dB based on parameter values reported by Nelson et al. (2011), which correspond to data from Nagatani et al. from bovine femur (2008).

Mean ± Std. Deviation (RMSE) Mean ± Std. Deviation (RMSE)
Frequency (MHz) 1.0
Frequency Analysis Range (MHz) (flowfhigh) 0.25 – 1.6
Separation (theory) 0.38 0.95
Separation (numerical) 0.45 0.89
Thickness (mm) 6 15
Afast 1.00 1.00 ± 0.07 (0.07) 1.01 ± 0.19 (0.19)
Aslow 0.13 0.13 ± 0.01 (0.01) 0.13 ± 0.01 (0.01)
βfast (dB/cmMHz) 49.2 49.0 ± 1.6 (1.6) 48.7 ± 3.0 (3.0)
βslow (dB/cmMHz) 7.1 7.3 ± 0.6 (0.6) 7.2 ± 0.3 (0.4)
vfast (ω0) (m/s) 1933 1933 ± 5 (5) 1930 ± 16 (16)
vslow (ω0) (m/s) 1475 1475 ± 1 (1) 1475 ± 1 (1)