Skip to main content
. Author manuscript; available in PMC: 2021 Jun 30.
Published in final edited form as: J Acoust Soc Am. 2013 Apr;133(4):2490–2501. doi: 10.1121/1.4792935

Table V.

Means, standard deviations, and root-mean-square errors (RMSE) for parameter estimates from simulations with SNR = 40 dB based on parameter values reported by Anderson et al. (2010) for data on human femur.

Mean ± Std. Deviation (RMSE)
Frequency (MHz) 0.5
Frequency Analysis Range (MHz) (flowfhigh) 0.2 – 0.8
Separation (theory) 0.56
Separation (numerical) 0.65
Thickness (mm) 16.8
Afast 0.82 0.85 ± 0.09 (0.09)
Aslow 0.23 0.24 ± 0.01 (0.01)
βfast (dB/cmMHz) 42.8 43.2 ± 1.6 (1.7)
βslow (dB/cmMHz) 5.2 5.5 ± 0.3 (0.4)
vfast (ω0) (m/s) 2036 2037 ± 4 (4)
vslow (ω0) (m/s) 1511 1511 ± 1 (1)