Skip to main content
. 2021 Aug;11(8):3604–3618. doi: 10.21037/qims-20-1365

Table 7. Comparison of Diagnostic Performance for Different Nodule Sizes in Various Guidelines.

Guideline Nodule size Sensitivity
(%)
Specificity
(%)
Positive predictive
value (%)
Negative predictive
value (%)
Accuracy
(%)
ACR TI-RADS 2017 <10 mm 94.37 63.04 71.16 92.06 78.44
≥10 mm 92.33 84.11 67.77 96.81 86.30
ATA 2016 <10 mm 96.80 57.14 69.24 94.71 76.94
≥10 mm 95.86 74.97 57.69 98.07 80.45
K-TIRADS 2016 <10 mm 94.37 62.72 70.98 92.02 78.28
≥10 mm 82.58 86.51 68.90 93.21 85.46
C-TIRADS 2020 <10 mm 74.17 84.48 82.20 77.19 79.41
≥10 mm 78.05 95.33 85.82 92.31 90.74

Data in parentheses are the raw data used to calculate the percentages. ACR-TIRADS 2017, the 2017 Thyroid Imaging Reporting and Data System of the American College of Radiology (10); ATA 2016, the 2016 American Thyroid Association guideline (11); K-TIRADS 2016, the 2016 Thyroid Imaging Reporting and Data System of the Korean Thyroid Association/Korean Society of Thyroid Radiology (5); C-TIRADS 2020, the 2020 Chinese Thyroid Imaging Reporting and Data System (3).