. 2020 Nov 28;45(5):464–472. doi: 10.1111/aor.13843

TABLE 5.

Survival during LVAD support (multivariable Cox proportional hazard model with DLI as time‐dependent covariate)

Variables Hazard ratio Confidence interval (95%) P value
Age at implant, years 1.062 1.006‐1.112 .030
Gender, female 0.306 0.072‐1.309 .110
BMI, kg/m2 1.056 0.886‐1.259 .540
Smoking history 1.629 0.698‐3.806 .259
Diabetes 1.457 0.732‐2.899 .284
DLI 1.001 0.999‐1.002 .155
Device
HeartMate II ref
HVAD 0.734 0.302‐1.78 .494
HeartMate 3 0.387 0.076‐1.966 .252
Strategy
Bridge to candidacy ref
Bridge to transplantation 0.107 0.030‐0.379 .001
Destination therapy 0.433 0.128‐1.130 .082
Bridge to recovery
INTERMACS level 0.996 0.714‐1.389 .982

Bold values indicates P‐values <0.05.

Abbreviations: BMI, body mass index; DLI, pump‐related percutaneous driveline infection; INTERMACS, Interagency Registry for Mechanically Assisted Circulatory Support; LVAD, left ventricular assist device; ref, reference.