Skip to main content
. Author manuscript; available in PMC: 2021 Jul 15.
Published in final edited form as: Atmos Environ (1994). 2020 May 6;233:117519. doi: 10.1016/j.atmosenv.2020.117519

Table 1:

Details of co-locations with reference instruments

Dates Reference Instrument Pollutants Location
Pre: 8/1 – 8/4/2016 aBaseline Mocon Series 900 Analyzer CH4, TNMHCs Los Angeles, CA
Post: 10/20 −10/28/2016 aPicarro cavity ring-down spectrometer CH4 Los Angeles, CA
Post: 11/2 – 11/12/2016 bSynspec Alpha 115 TNMHCs Shafter, CA
a

operated by SCAQMD,

b

operated by SJVAD