Skip to main content
. 2021 Mar 7;15(8):1814–1824. doi: 10.1049/ipr2.12153

TABLE 4.

Accuracy metrics in terms of true positive (TP), true negative (TN), false positive (FP), false negative (FN), accuracy, specificity, sensitivity and precision

Metrics
Architecture Classes TP TN FP FN Accuracy Specificity Sensitivity Precision Total
Proposed CNN Architecture Mild 186 442 10 14 96.32% 0.978 0.930 0.949 200
Moderate 181 448 14 9 96.47% 0.970 0.953 0.928 190
Severe 139 507 3 3 99.08% 0.994 0.979 0.979 142
Critical 116 529 3 4 98.93% 0.994 0.967 0.967 120

This article is being made freely available through PubMed Central as part of the COVID-19 public health emergency response. It can be used for unrestricted research re-use and analysis in any form or by any means with acknowledgement of the original source, for the duration of the public health emergency.