Table 2.

Room temperature fluorescence quantum yields (ϕF) and emission lifetimesai) for compounds D1 and D2 in pure solvents. Also presented are the associated pre‐exponential factors (ai), the fractional contributions for each decay time (%Ci), and the chi‐square values (χ2) for the judgment of the quality of the fits. Radiative (kF) and radiationless rate (kNR) constants associated with the third decay component (τ3) are also listed.

Dye

Solvent

Concentration [μM]

ϕF

τ1 [ns]

a1 [C1%]

τ2 [ns]

a2 [C2%]

τ3 [ns]

a3 [C3%]

χ2

b)kF ×10−6 [s−1]

c) kNR ×10−8 [s−1]

D1

THF

50

0.013

4.07

1 (100)

0.69

3.19

2.43

DCM

50

0.102

5.41

1 (100)

0.81

18.9

1.66

MeOH

50

0.002

0.16

0.889 (44)

1.18

0.096 (35)

4.40

0.015 (21)

1.04

0.46

2.27

ACN

50

0.11

4.36

1 (100)

0.70

25.2

2.04

Film

0.007

0.14

0.968 (50)

4.27

0.032 (50)

1.09

1.64

2.36

D2

THF

50

0.001

0.34

0.902 (62)

1.51

0.089 (27)

5.65

0.010 (11)

0.92

0.18

1.77

DCM

50

0.022

1.21

0.146 (5.5)

3.55

0.854 (94.5)

0.68

6.2

2.75

MeOH

5

0.067

13.31

0.026 (7.0)

4.56

0.974 (93)

1.16

14.7

2.05

10

0.018

13.30

0.028 (8.0)

4.5

0.972 (92)

1.04

4.0

2.18

25

0.003

0.42

0.894(30)

18.65

0.025 (37)

5.03

0.081 (33)

1.01

0.60

1.98

50

0.001

0.48

0.797 (22)

21.21

0.019 (24)

5.02

0.184 (54)

1.11

0.20

1.99

ACN

50

0.008

2.36

1 (100)

0.6

3.4

4.20

Film

0.001

0.19

0.996 (92)

4.17

0.004 (8)

0.82

0.24

2.40

[a] Experimental conditions: λex=460 nm [b] kF=ϕFτF . [c] kNR=1-ϕFτF .