Table 6.

The energy needed for the steps of the process (Including the vaccination centres and waste treatment).

Equipment Power (W) Operation time (h) Energy consumed (kWh) Energy consumed for 1 M doses (kWh) Total CO2 emission (kg) Total emission for 1 M doses (kg CO2) References
Disinfectant
Continuous stirred-tank reactor 4,500 24
  • •108 (for 1t production)

  • •2.26* (required for 1,000 vaccinations)

* The value 2.26 kWh is assumed for the 1,000 doses of vaccine /d. The 4 × 3 m area required a disinfectant of 9 L/d. The 10 L/d disinfectant needs to be used by sanitation walkthrough for 1,000 person/doses vaccinated [42].
2,260
  • •44.3 (against 108 kWh of energy consumed)

  • •0.92*

*The value 0.92 kg of CO2 is assumed for the 1,000 doses of vaccine/d.
920 [43]
Vaccine vials manufacturing
Furnace (water removal) 7,083 24
  • 170 (for 1 t of glass)

  • 26.6*

*The value 26.6 kWh is assumed for the 1,000 vials/d.
26,600
  • 69.7 (against 170 kWh of energy consumed)

  • 1.70

*The value 0.92 kg of CO2 is assumed for the 1,000 doses of vaccine/d.
1,700 [48]
Furnace (dry process) 18,333 24
  • 440 (for 1t of glass)

  • 44.3*

*The value 44.3 kWh is assumed for the 1,000 vials/d.
44,300
  • 180.4 (against 440 kWh of energy consumed)

  • 2.79

*The value 2.79 kg of CO2 is assumed for the 1,000 doses of vaccine/d.
2,790
Furnace (wet process) 33,041 24
  • 793 (for 1t of glass)

  • 80.1*

*The value 44.3 kWh is assumed for the 1,000 vials/d.
80,100
  • 325.5 (against 793 kWh of energy consumed)

  • 2.79

*The value 2.79 kg of CO2 is assumed for the 1,000 doses of vaccine/d.
5,585
Syringes for vaccination manufacturing
Hydraulic moulding 213 24 5.12 5,120*
* It's also include the needle manufacturing and syringe sterilisation energy
2.09 2,090 [52]
Electric moulding 159 24 2.55 2,550 1.04 1,040
Hybrid moulding 106 24 3.83 3,830 1.57 1,570
All healthcare facilities for 1,000 doses/d (Vaccination centre with a staff of 5 persons)
Lights (fluorescent) 11 6 0.066 66 0.41 kg of CO2/kWh of energy [68]
Mobile phone charger 5–20 8 0.04–0.16 160
Ceiling fan (CD, AC) 30–100 10 0.3–1.0 1,000
All healthcare facilities
Water pump 100 6 0.6 600 0.41 kg of CO2/kWh of energy
Computer 15–200 4 0.06–0.8 800
Heating and air conditioning 1,000–1,500 4 4–7.5 7,500
Others (TV, Audio/Visual device) 2–30 8 0.016–0.24 240
Vaccination centre laboratory equipment
Vaccine refrigerator (165 L) 40–500 4 0.16–2 2,000 0.41 kg of CO2/kWh of energy