Skip to main content
. 2021 May 19;16(7):1111–1119. doi: 10.1007/s11548-021-02388-z

Table 4.

TeCNO vs MTMS-TCN: 4-fold cross-validation average precision, recall, and F1-score (%) reported for the critical steps

TeCNO MTMS-TCN
ID PR RE F1 PR RE F1
S4 84.2±5.7 90.0±3.8 85.6±4.1 86.4±10.8 88.3±3.9 86.1±6.6
S5 87.7±1.7 80.4±9.4 80.8±7.6 87.5±4.3 77.4±6.7 79.2±6.8
S6 77.4±7.8 64.7±22.3 63.0±16.3 76.4±15.8 66.9±22.5 62.5±13.6
S7 77.2±10.1 64.7±11.8 67.8±9.3 72.1±8.0 64.0±10.7 66.4±9.8
S8 78.0±8.3 77.1±10.5 72.8±4.0 75.6±7.0 77.1±9.8 72.7±3.4
S16 76.4±7.1 69.1±6.5 68.7±4.2 79.1±3.2 67.7±4.0 68.6±4.4
S18 92.4±2.3 83.1±5.3 86.6±2.3 89.8±4.9 80.5±3.1 83.4±3.6
S25 55.1±12.4 39.4±18.6 40.6±16.1 47.6±6.6 49.5±18.3 45.2±10.7
S30 62.3±4.8 62.0±13.5 57.5±10.3 65.3±6.7 71.2±5.2 64.8±5.6
S32 87.9±3.8 85.4±4.4 84.0±6.6 85.1±5.4 86.3±3.3 83.7±2.9
S39 46.2±27.1 47.8±25.4 39.0±22.2 49.6±33.9 42.9±27.2 40.6±25.5

Bold numbers denote best performance per step per metric