Skip to main content
. 2021 Jul 6;11:13911. doi: 10.1038/s41598-021-92670-6

Table 2.

Sensations felt by athletes during high-definition (HD), conventional, and active sham transcranial direct current stimulation (n = 12).

Sensation High definition Conventional Sham χ2 P
Itching 1.0 (0.0–2.0) 1.0 (0.0–1.5) 1.5 (0.0–2.0) 0.261 0.878
Pain 0.0 0.0 0.0 N/A N/A
Burning 0.0 (0.0–0.0) 0.0 (0.0–0.75) 0.0 (0.0–0.75) 1.0 0.607
Warmth/Heat 0.0 (0.0–1.0) 0.0 (0.0–0.75) 0.0 (0.0–1.0) 1.08 0.584
Pinching 1.0 (1.0–1.0) 1.5 (1.0–2.0) 1.0 (1.0–2.0) 0.75 0.687
Metallic/Iron taste 0.0 (0.0–0.0) 0.0 (0.0–0.0) 0.0 (0.0–0.0) 2.0 0.368
Fatigue 0.0 0.0 0.0 N/A N/A
Beginning 1.0 (1.0–1.75) 1.0 (1.0–1.0) 1.0 (1.0–1.75) 0.5 0.779
Duration 2.0 (1.0–3.0) 3.0 (2.0–3.0) 2.0 (1.25–3.0) 3.56 0.169
Affect performance 0.0 0.0 0.0 N/A N/A

Data described as median (interquartile range); N/A = not applicable.