Skip to main content
. 2021 Jun 23;12:674962. doi: 10.3389/fpsyt.2021.674962

Table 2.

Relationships of trial conditions with responses.

Response Number of responses Prop. of responses (%) Lead contact Voltage Frequency Diagnosis Patient
Numbness 146 66.7 0.197 0.015* 0.702 0.848 <0.0001***
Changes in heart rate 79 36.1 0.635 0.071 <0.0001*** <0.0001*** <0.0001***
Pain 37a 16.9 0.573 0.425 0.454 <0.0001*** <0.0001***
Dizziness 35 16 0.002** 0.001** 0.003** 0.447 0.001**
Eye closure 24b 11 0.595 0.335 0.157 0.058 <0.0001***
Giddiness 18 8.2 0.036* <0.0001*** <0.0001*** 0.001** <0.0001***
Involuntary movements 18c 8.2 0.008** 0.534 0.553 0.001** <0.0001***

Responses that occurred in <5% of the trials or in only one patient were omitted. Prop, proportion.

*

p < 0.05;

**

p < 0.01;

***

p < 0.001.

The total number of trials was 219.

a

36 reported in a patient with schizophrenia;

b

15 reported in another patient with schizophrenia;

c

12 reported in a patient with bipolar disorder.