Skip to main content
. Author manuscript; available in PMC: 2021 Jul 7.
Published in final edited form as: Heart Rhythm. 2018 Jun 2;15(11):1617–1625. doi: 10.1016/j.hrthm.2018.05.031

Table 2:

Electrogram Characteristics within Scar, Border Zone, and Normal Myocardium

Dense Scar Border Zone Normal Myocardium
Thermocool
Bipolar Voltage (mV) 0.30 (0.04 – 0.498) 0.93 (0.501 – 1.49) 3.6 (1.5 – 14.8)
Unipolar Voltage (mV) 3.09 (0.93 – 7.63) 4.5 mV (1.18 – 11.3) 8.2 (2.6 – 23.5)
EGM Duration (ms) 146 (64–232) 137 (74–235) 118 (48–231)
PentaRay
Bipolar Voltage (mV) 0.27 (0.036 – 0.498) 0.85 (0.501 – 1.497) 4.42 (1.5 – 29.3)
Unipolar Voltage (mV) 4.13 (0.73 – 12.38) 5.50 (0.85 – 14.07) 8.87 (1.61 – 31.22)
EGM Duration (ms) 147 (56–268) 134 (71–228) 120 (57–280)

Values are shown as mean and 95% confidence interval. P<0.001 for between group differences (scar, border zone, normal myocardium) for each characteristic.