Table 3.
Consensus model results for the androgen binding receptor Tier 1 EDSP data set.
| Consensus II 3-models | Consensus II 2-models combinations | |||
|---|---|---|---|---|
| MD+D | AP+D | MD+AP | ||
| TP | 3 | 2 | 3 | 3 |
| TN | 26 | 12 | 24 | 9 |
| FN | 7 | 8 | 7 | 7 |
| FP | 5 | 19 | 7 | 24 |
| Sn | 0.30 | 0.20 | 0.30 | 0.30 |
| Sp | 0.84 | 0.39 | 0.77 | 0.27 |
| Accuracy | 0.71 | 0.34 | 0.66 | 0.28 |
| Balanced accuracy | 0.57 | 0.30 | 0.54 | 0.29 |
| PPV | 0.38 | 0.10 | 0.30 | 0.11 |
| NPV | 0.79 | 0.60 | 0.77 | 0.56 |
| MCC | 0.15 | −0.35 | 0.07 | −0.37 |
TP:true positives, TN:true negatives, FN:false negatives, FP:false positives, Sn:sensitivity, Sp:specificity, PPV:positive predictive value, NPV:negative predictive value, MCC:Matthews correlation coefficient, MD:MetaDrug, AP:ADMET Predictor, D:Endocrine Disruptome.