Skip to main content
. 2021 Jun 22;14(13):3440. doi: 10.3390/ma14133440

Table 3.

Design matrix and response value for the fire resistance test.

Sample Coded Factors Uncoded Factors Responses Sample Coded Factors Uncoded Factors Responses
A B A B TT200 TAE A B A B TT200 TAE
S1 −0.500 0.500 20 80 168 439 S21 0.000 0.000 30 70 202 332
S2 0.000 −1.000 30 50 246 274 S22 0.000 0.000 30 70 201 331
S3 −0.500 −0.500 20 60 192 421 S23 0.000 0.000 30 70 198 330
S4 0.000 1.000 30 90 197 425 S24 −1.000 0.000 10 70 164 481
S5 0.500 0.500 40 80 198 285 S25 −0.500 0.500 20 80 172 445
S6 0.500 0.500 40 80 201 287 S26 1.000 0.000 50 70 315 236
S7 0.000 0.000 30 70 198 330 S27 1.000 0.000 50 70 314 237
S8 0.000 0.000 30 70 198 333 S28 0.500 −0.500 40 60 251 261
S9 0.000 0.000 30 70 201 331 S29 −1.000 0.000 10 70 162 487
S10 0.000 0.000 30 70 209 337 S30 0.000 0.000 30 70 199 331
S11 0.000 0.000 30 70 199 331 S31 0.000 0.000 30 70 202 336
S12 0.000 0.000 30 70 201 334 S32 0.000 0.000 30 70 200 330
S13 0.500 −0.500 40 60 246 258 S33 0.500 −0.500 40 60 248 259
S14 0.000 0.000 30 70 199 330 S34 −0.500 0.500 20 80 173 441
S15 0.000 0.000 30 70 201 333 S35 0.000 0.000 30 70 202 332
S16 −0.500 −0.500 20 60 190 419 S36 0.000 1.000 30 90 195 425
S17 0.000 1.000 30 90 195 423 S37 0.000 −1.000 30 50 243 269
S18 1.000 0.000 50 70 312 239 S38 0.500 0.500 40 80 203 287
S19 0.000 −1.000 30 50 240 266 S39 −0.500 0.500 20 80 163 483
S20 −0.500 −0.500 20 60 186 418

TAE = Temperature at equilibrium (in °C); TT200 = Time taken to reach 200 °C (in seconds).