Skip to main content
. 2021 Jun 22;14(13):3440. doi: 10.3390/ma14133440

Table 6.

Experimental validation for the fire resistance test.

TT200 (s) TAE (°C)
Experimental Value Predicted Value Error (%) Experimental Value Predicted Value Error (%)
SV1 298 320 6.88 227 206 10.19
SV2 311 320 2.81 212 206 2.91
SV3 307 320 4.06 219 206 6.31
Error 4.58 Error 6.47

SV = Sample validation.