Skip to main content
. 2021 Jul 5;14(13):3758. doi: 10.3390/ma14133758

Table 12.

The average amount of Fe, Ni, Cr, and Mn ions being measured when 300 mV or 750 mV was applied on the three different dimensions of the SS wires.

Applied Potential on the SS Wires in mV Average Amount of Iron
Ions in µg/L
SD Average Amount of Nickel Ions in µg/L SD Average Amount of Chromium Ions in µg/L SD Average Amount of Manganese Ions in µg/L SD
300 431.252 752.796 57.394 103.333 102.998 195.985 11.344 14.748
750 341.613 705.092 45.697 95.528 83.093 158.971 8.967 12.435