PHY operating modes [16].

Modulation RLL Code Optical Clock Rate (kHz) FEC Data Rate (kbps)
Outer Code (RS) Inner Code (CC)
OOK Manchester 200 (15, 7) 1/4 11.67
(15, 11) 1/3 24.44
(15, 11) 2/3 48.89
(15, 11) none 73.3
none none 100
VPPM 4B6B 400 (15, 2) none 35.56
(15, 4) none 71.11
(15, 7) none 124.4
none none 266.6