Skip to main content
. 2021 Jun 29;21(13):4441. doi: 10.3390/s21134441

Table 3.

Regression analysis of the differences (Coefficient (slope and intercept), SE = standard error) together with the 95 % confidence intervals (CI), p-values and coefficient of repeatability (CR) of the spatiotemporal parameters between the OptoGaitTM (O) and the Xsens (X).

SPT (O-X) Parameter Coefficient SE t p 95% CI CR 95% CI
Stance phase (s) Intercept 0.096 0.033 2.900 0.0041 0.030 to 0.162 0.121 0.110 to 0.134
Slope −0.059 0.049 −1.192 0.2346 −0.157 to 0.038
Swing phase (s) Intercept −0.046 0.029 −1.569 0.1182 −0.104 to 0.011 0.056 0.0514 to 0.0623
Slope 0.093 0.087 1.065 0.2878 −0.079 to 0.265
Stance phase (%) Intercept 21.820 8.805 2.478 0.0140 4.461 to 39.180 7.378 6.733 to 8.160
Slope −0.284 0.132 −2.141 0.0334 −0.545 to −0.0225
Swing phase (%) Intercept 8.821 4.792 1.840 0.0671 −0.627 to 18.269 7.327 6.687 to 8.104
Slope −0.347 0.142 −2.444 0.0153 −0.627 to −0.0672
Gait Cycle (s) Intercept −0.039 0.032 −1.219 0.2239 −0.102 to 0.0242 0.091 0.083 to 0.101
Slope 0.080 0.032 2.496 0.0133 0.016 to 0.143
Double support (s) Intercept 0.127 0.033 3.826 0.0002 0.061 to 0.193 0.158 0.144 to 0.175
Slope −0.168 0.101 −1.666 0.0971 −0.368 to 0.030
Double support (%) Intercept 11.653 4.390 2.654 0.0086 2.997 to 20.308 13.531 12.349 to 14.966
Slope −0.177 0.134 −1.316 0.1896 −0.442 to 0.088
Pre-swing (s) Intercept 0.054 0.018 2.964 0.0034 0.018 to 0.089 0.0834 0.076 to 0.0927
Slope −0.108 0.110 −0.977 0.3295 −0.326 to 0.110
Pre-swing (%) Intercept 29.749 1.602 18.564 <0.0001 26.590 to 32.909 10.447 9.534 to 11.554
Slope −1.654 0.093 −17.682 <0.0001 −1.839 to −1.470
Loading response (%) Intercept −26.826 0.864 −31.042 <0.0001 −28.529 to −25.122 23.984 21.889 to 26.527
Slope 1.844 0.044 41.031 <0.0001 1.756 to 1.933
Cadence (step/min) Intercept −2.893 3.864 −0.748 0.4549 −10.512 to 4.725 10.935 9.980 to 12.095
Slope −0.016 0.032 −0.516 0.6058 −0.080 to 0.046