Skip to main content
. 2021 Jul 4;21(13):4582. doi: 10.3390/s21134582

Table 2.

Confusion matrix of the testing results.

Intec/HU YOLOv4
Threshold = 0.1 Threshold = 0.5 Threshold = 0.7
Asbestos Non-Asbestos Asbestos Non-Asbestos Asbestos Non-Asbestos Asbestos Non-Asbestos
Manually counted (NIOSH 7400) Asbestos 46 13 54 5 53 6 52 7
Non-asbestos 64 3586 12 3638 6 3644 5 3645
Accuracy 0.979 0.995 0.997 0.997
Precision 0.418 0.818 0.898 0.912
Recall 0.780 0.915 0.898 0.881
F1-score 0.544 0.864 0.898 0.897