Table 2.
Use of body-worn sensors to assess fall risk
| Assessment while sensor was used | Applied sensors (range of sampling rates in Hertz) | Body location | Assessed variables |
|---|---|---|---|
|
gait analysis (between 7.62 and 400 m) |
DynaPort, Trigno wireless systems, Locometrix, X16-1C, ActiGraph, GT3X+, Freescale, DAAF, ETB-Pegasus (30 Hz–296.3 Hz) |
head, waist, lower back, pelvis |
temporal and spatial gait variables, local dynamic stability variables, variables of gait symmetry, acceleration variables, angle variables |
|
daily-life walking between three to eight days |
Senior Mobility Monitor, SHIMMER platform, DynaPort, Opal, BMA280 (50 Hz–128 Hz) |
chest, lower back, wrist, upper legs, lower legs |
temporal and spatial gait variables, variables of gait symmetry and gait variability, variables of gait complexity and gait smoothness, angle variables, acceleration variables |
|
Timed-Up and Go Test |
SHIMMER platform, Freescale, Opal, Mobi8 System, combined sensor (100 Hz–256 Hz) |
chest, waist, lower back, upper legs, foot |
temporal and spatial gait variables, angular velocity variables, energy variables, angle variables |
| Tinetti Test [19] |
GENEActiv (50 Hz) |
chest | temporal and spatial gait variables, balance variables |
| six-minutes walking test [64] |
DYSKIMOT (100 Hz) |
lower back |
acceleration variables, variables of gait variability |
| others | |||
| standardized protocol with walking and sit to stand transitions [60] |
not specified (50 Hz) |
around the neck |
temporal gait variables, acceleration variables |
| specially developed test battery [50] |
Xsens (100 Hz) |
lower back, upper legs, lower legs |
temporal and spatial gait variables, angle variables, angular velocity variables, |
| semi-unsupervised walking and stair ascent and descent [46] | Opal (128 Hz) | lower back, ankle |
temporal gait variables, variables of gait variability, variables of movement vigour |
All applied sensors contained an accelerometer, a gyroscope or a combination of both