Skip to main content
. 2021 Jul 12;9(1):30. doi: 10.1007/s13755-021-00159-3

Table 4.

10-fold cross-validation results for hand tremor detection algorithms with different classification models

Hand tremor detection algorithms with different classification models Average accuracy Average precision Average recall Average F1 score
MDC with SVM model (benchmark) 0.55 0.53 0.65 0.58
DIST + MDC with SVM model 0.56 0.53 0.67 0.59
DIST + MDC with LSTM model 0.80 0.79 0.79 0.79
DIST + MDC with CNN-LSTM model 0.81 0.81 0.79 0.80