Table 3.
Maximum values for the numerical risk factors (RFs) for ABS and COMP stents under P1, P2 and P3 loads combinations and the corresponding experimental results.
| STENT ABS | FEA | EXP | ||||
|---|---|---|---|---|---|---|
| Fatigue criteria | Output | # tests | ||||
| Load case | VM | FS | BM | SWT | ||
| P1 | 1.79 | 0.91 | 0.83 | 0.84 | 2 Run-out | 2 |
| P2 | 2.79 | 1.31 | 1.22 | 1.25 | 3 Failure | 3 |
| P3 | 1.94 | 0.97 | 0.86 | 0.90 | 3 Run-out | 3 |
| STENT COMP | FEA | EXP | ||||
| Fatigue criteria | Output | # tests | ||||
| Load case | VM | FS | BM | SWT | ||
| P1 | 1.54 | 1.00 | 0.84 | 0.84 | 2 Run-out | 2 |
| P2 | 3.40 | 2.22 | 2.01 | 1.31 | 3 Failure | 3 |
| P3 | 1.87 | 1.17 | 1.00 | 0.85 | 2 Run-out | 2 |